This toroid is dedicated to Vigilohm Insulation Fault locators, and to VigiPacT type A residual current protection and monitoring relays. It allows the monitoring of the injected component from Vigilohm Insulation Monitor, and the measurement of a current rating up to 630A for VigiPacT monitoring and protection relays. The transformer ratio is 1/1000. The inner diameter of the toroid is 300 millimeters and the weight is 2.280kg. The cables must be centered within the toroid and the diameter represented by all these cables should not exceed 150 millimeters. The maximum cross section per phase (R, S, T, N) is 2 cables of 240mm² for a copper conductor.
Closed toroid A type, VigiPacT, Vigilohm, GA300, inner diameter 300mm, rated current 630A
Closed toroid A type, VigiPacT, Vigilohm, GA300, inner diameter 300mm, rated current 630A
SKU: 485860
Category: Circuit Breakers
Reviews (0)
Be the first to review “Closed toroid A type, VigiPacT, Vigilohm, GA300, inner diameter 300mm, rated current 630A” Cancel reply
Related products
Miniature circuit breaker (MCB), Multi9 C60N, 4P, 4A, C curve, 10kA (IEC/EN 60947-2)
Miniature circuit breaker (MCB), Multi9 C60N, 4P, 4A, C curve, 10kA (IEC/EN 60947-2)
Automatic switch, PowerPacT J, 225A, 3 pole, 600VAC, 50kA, lugs, magnetic
Automatic switch, PowerPacT J, 225A, 3 pole, 600VAC, 50kA, lugs, magnetic
Circuit breaker, PowerPacT H, 100A, 3 pole, 600VAC, 50kA, I-Line, Micrologic 5.2E, 80%, ABC
Circuit breaker, PowerPacT H, 100A, 3 pole, 600VAC, 50kA, I-Line, Micrologic 5.2E, 80%, ABC
Circuit breaker frame, MasterPact MTZ2 32H2, 3200A, 100kA/440VAC 50/60Hz (Icu), 4P, drawout, without control unit
Circuit breaker frame, MasterPact MTZ2 32H2, 3200A, 100kA/440VAC 50/60Hz (Icu), 4P, drawout, without control unit
Circuit breaker, PowerPacT H, 15A, 3 pole, 600VAC, 25kA, lugs, thermal magnetic, 80%, shunt
Circuit breaker, PowerPacT H, 15A, 3 pole, 600VAC, 25kA, lugs, thermal magnetic, 80%, shunt
Circuit breaker, PowerPacT P, I-Line, Micrologic 5.0, 400A, 3 pole, 25kA, 600VAC, phase ABC, shunt trip, 80% rated
Circuit breaker, PowerPacT P, I-Line, Micrologic 5.0, 400A, 3 pole, 25kA, 600VAC, phase ABC, shunt trip, 80% rated
Circuit breaker, PowerPacT J, 200A, 3 pole, 600VAC, 18kA, lugs, thermal magnetic, 80%, aux
Circuit breaker, PowerPacT J, 200A, 3 pole, 600VAC, 18kA, lugs, thermal magnetic, 80%, aux
Circuit breaker, PowerPacT B, 20A, 1 pole, 600Y/347VAC, 25kA, I-Line, thermal magnetic, 80%, C
Circuit breaker, PowerPacT B, 20A, 1 pole, 600Y/347VAC, 25kA, I-Line, thermal magnetic, 80%, C
Reviews
There are no reviews yet.