PowerPacT L-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT L-Frame circuit breakers are available with electronic trip units. All PowerPacT L-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT L circuit breakers are available in 3 and 4-pole unit mount, I-Line, and drawout constructions. This PowerPacT L, 600A, 3 pole, circuit breaker has an interrupting rating of 65kA at 480VAC. This circuit breaker provides MicroLogic Standard with a 3.3S trip unit and an LSI function. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. This breaker is a PowerPact Mission Critical; it analyzes fault current to make decisions which maximize selectivity with downstream circuit breakers. PowerPacT L circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
Circuit breaker, PowerPact L, I-Line, Micrologic 3.3S, 600A, 3 poles, 480 V, 65 kA, 80% rated, mission critical
Circuit breaker, PowerPact L, I-Line, Micrologic 3.3S, 600A, 3 poles, 480 V, 65 kA, 80% rated, mission critical
SKU: 16782082
Category: Molded Case Breakers
Reviews (0)
Be the first to review “Circuit breaker, PowerPact L, I-Line, Micrologic 3.3S, 600A, 3 poles, 480 V, 65 kA, 80% rated, mission critical” Cancel reply
Related products
Circuit breaker, PowerPact H, I Line, thermal magnetic, 70A, 3 pole, 600V, 25kA, phase CBA
Circuit breaker, PowerPact H, I Line, thermal magnetic, 70A, 3 pole, 600V, 25kA, phase CBA
Circuit breaker, PowerPact B, 30A, 1 pole, 600Y/347V AC, 14kA at 600Y/347 UL, terminal nuts
Circuit breaker, PowerPact B, 30A, 1 pole, 600Y/347V AC, 14kA at 600Y/347 UL, terminal nuts
Circuit breaker, PowerPact B, 100A, 3 poles, 600Y/347V AC, 25kA at 600Y/347 UL, terminal nuts
Circuit breaker, PowerPact B, 100A, 3 poles, 600Y/347V AC, 25kA at 600Y/347 UL, terminal nuts
PowerPact B Circuit Breaker, 50A, 3P, 600Y/347V AC, 25kA at 600Y/347 UL, I-Line
PowerPact B Circuit Breaker, 50A, 3P, 600Y/347V AC, 25kA at 600Y/347 UL, I-Line
Circuit breaker, PowerPacT B, 100A, 1 pole, 480Y/277VAC, 18kA, I-Line, thermal magnetic, 80%, A
Circuit breaker, PowerPacT B, 100A, 1 pole, 480Y/277VAC, 18kA, I-Line, thermal magnetic, 80%, A
Circuit breaker, PowerPact B, 80A, 3 poles, 600Y/347V AC, 18kA at 600Y/347 UL, terminal nuts
Circuit breaker, PowerPact B, 80A, 3 poles, 600Y/347V AC, 18kA at 600Y/347 UL, terminal nuts
Circuit breaker, PowerPact H, thermal magnetic, 70A, 3 pole, 600V, 25kA
Circuit breaker, PowerPact H, thermal magnetic, 70A, 3 pole, 600V, 25kA

Reviews
There are no reviews yet.