The PowerPact H-, J-, and L-frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. H- and J-frame circuit breakers are available with either thermal-magnetic or Micrologic electronic trip units. The new generation PowerPact with Micrologic circuit breakers set the standard with direct access to energy management. Integrated metering enhances their protective functions. For the first time, Schneider Electric™ users can monitor energy from 15 to 3000 A, offering new performance in a remarkably compact device. This PowerPact H, circuit breaker has a rated current of 150A and is a 3P breaker. This breaker has a breaking capacity of 14 kA@600VAC and has an trip technology. This breaker complies to UL, CE, IEC & CSA standards. Thermal current for this breaker has a magnetic tripping current of 1450A. Dimensions for this breaker are 6.4 in (H),4.12 in (W),4.36 in (D) and has an ambient temperature of 40 °C. This product comes with an 18 months warranty.
Circuit breaker, PowerPacT H, NO TRIP UNIT, unit mount, 150A, 3 pole, 25 kA, 600 VAC, 80% rated
Circuit breaker, PowerPacT H, NO TRIP UNIT, unit mount, 150A, 3 pole, 25 kA, 600 VAC, 80% rated
SKU: 8997248
Category: Circuit Breakers
Reviews (0)
Be the first to review “Circuit breaker, PowerPacT H, NO TRIP UNIT, unit mount, 150A, 3 pole, 25 kA, 600 VAC, 80% rated” Cancel reply
Related products
Mini CB, QO, 50 A, 1P, 120/240 V, 10 kA, Bolt on, 50Deg
Mini CB, QO, 50 A, 1P, 120/240 V, 10 kA, Bolt on, 50Deg
Second MX voltage release, MasterPact MTZ1 drawout, remote tripping, 277VAC 50/60Hz
Second MX voltage release, MasterPact MTZ1 drawout, remote tripping, 277VAC 50/60Hz
Circuit breaker, PowerPacT M, 600A, 3 pole, 600VAC, 18kA, lugs, ET 1.0, 80%
Circuit breaker, PowerPacT M, 600A, 3 pole, 600VAC, 18kA, lugs, ET 1.0, 80%
Circuit breaker, PowerPacT B, 20A, 1 pole, 600Y/347VAC, 25kA, I-Line, thermal magnetic, 80%, C
Circuit breaker, PowerPacT B, 20A, 1 pole, 600Y/347VAC, 25kA, I-Line, thermal magnetic, 80%, C
Circuit breaker, PowerPact L, unit mount, Micrologic 3.3S, 600A, 3 pole, 35kA, 480VAC, 80% rated, mission critical
Circuit breaker, PowerPact L, unit mount, Micrologic 3.3S, 600A, 3 pole, 35kA, 480VAC, 80% rated, mission critical
Circuit breaker, PowerPacT B, 125A, 1 pole, 600Y/347VAC, 18kA, I-Line, thermal magnetic, 80%, A
Circuit breaker, PowerPacT B, 125A, 1 pole, 600Y/347VAC, 18kA, I-Line, thermal magnetic, 80%, A
Circuit breaker, PowerPacT H, 100A, 3 pole, 600VAC, 50kA, I-Line, Micrologic 5.2E, 80%, ABC
Circuit breaker, PowerPacT H, 100A, 3 pole, 600VAC, 50kA, I-Line, Micrologic 5.2E, 80%, ABC
Circuit breaker, PowerPacT P, 800A, 3 pole, 600VAC, 25kA, I-Line, Micrologic 5.0H, 80%, ABC, modbus
Circuit breaker, PowerPacT P, 800A, 3 pole, 600VAC, 25kA, I-Line, Micrologic 5.0H, 80%, ABC, modbus
Reviews
There are no reviews yet.