Square D LA molded case circuit breakers provide thermal magnetic protection. Their primary function is automatic opening of a circuit under overload or short circuit conditions or manual opening. LA circuit breakers contain thermal (overload) and magnetic (short circuit) sensing elements in each pole. Push-to-Trip allows the circuit breaker to be manually tripped without exposure to live parts. This Square D LA molded case circuit breaker is a 2 pole unit mount breaker, 400A and 600VAC, with lugs. The thermal magnetic circuit breaker has an interrupting rating of 22kA for 600VAC and 10kA for 250VDC. The circuit breaker MB suffix indicates a shorter handle so that a panel door can close. LA breakers are UL 489, CSA, IEC certified.
Circuit breaker, LA, 400A, 2 pole, 600VAC, 22kA, 250VDC, 10kA, lugs, thermal magnetic, short handle
Circuit breaker, LA, 400A, 2 pole, 600VAC, 22kA, 250VDC, 10kA, lugs, thermal magnetic, short handle
SKU: 172546649
Category: Circuit Breakers
Reviews (0)
Be the first to review “Circuit breaker, LA, 400A, 2 pole, 600VAC, 22kA, 250VDC, 10kA, lugs, thermal magnetic, short handle” Cancel reply
Related products
Miniature circuit breaker (MCB), Multi9 C60BP, 1P, 5A, D curve, 14kA (UL489), 10kA (IEC/EN 60947-2)
Miniature circuit breaker (MCB), Multi9 C60BP, 1P, 5A, D curve, 14kA (UL489), 10kA (IEC/EN 60947-2)
Miniature circuit breaker (MCB), Multi9 C60N, 4P, 4A, C curve, 10kA (IEC/EN 60947-2)
Miniature circuit breaker (MCB), Multi9 C60N, 4P, 4A, C curve, 10kA (IEC/EN 60947-2)
Circuit breaker, PowerPact L, unit mount, Micrologic 3.3S, 600A, 3 pole, 35kA, 480VAC, 80% rated, mission critical
Circuit breaker, PowerPact L, unit mount, Micrologic 3.3S, 600A, 3 pole, 35kA, 480VAC, 80% rated, mission critical
Circuit breaker, PowerPacT M, 600A, 3 pole, 600VAC, 18kA, lugs, ET 1.0, 80%
Circuit breaker, PowerPacT M, 600A, 3 pole, 600VAC, 18kA, lugs, ET 1.0, 80%
Circuit breaker, PowerPacT P, I-Line, Micrologic 5.0, 400A, 3 pole, 25kA, 600VAC, phase ABC, shunt trip, 80% rated
Circuit breaker, PowerPacT P, I-Line, Micrologic 5.0, 400A, 3 pole, 25kA, 600VAC, phase ABC, shunt trip, 80% rated
Circuit breaker, PowerPacT B, 70A, 4 pole, 600Y/347VAC, 18kA, lugs, thermal magnetic, 80%, control wire ON end
Circuit breaker, PowerPacT B, 70A, 4 pole, 600Y/347VAC, 18kA, lugs, thermal magnetic, 80%, control wire ON end
Circuit breaker, PowerPacT B, 30A, 3 pole, 600Y/347VAC, 14kA, lugs, thermal magnetic, 80%
Circuit breaker, PowerPacT B, 30A, 3 pole, 600Y/347VAC, 14kA, lugs, thermal magnetic, 80%
Circuit breaker, PowerPacT B, 15A, 3 pole, 600Y/347VAC, 14kA, I-Line, thermal magnetic, 80%, ABC
Circuit breaker, PowerPacT B, 15A, 3 pole, 600Y/347VAC, 14kA, I-Line, thermal magnetic, 80%, ABC
Reviews
There are no reviews yet.