Square D PowerPact H-frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits Molded case circuit breakers are available with either thermal-magnetic or Micrologic electronic trip units. The external neutral current transformer is a required sensor for 3 pole circuit breaker in a system with a distributed neutral to measure the neutral current in oder to protect neutrak conducter and protect against ground faults. This current trasformer could be used with H-frame PowerPacT circuit breakers with current rating 60 to 100A The neutral current transformer is connected in the same way for unit-mount, plug-in or drawout devices, cross-sectional area is AWG 22-AWG 16.
Circuit breaker accessory, PowerPacT H, Micrologic, external neutral current transformer, ENCT, 60A to 100A
Circuit breaker accessory, PowerPacT H, Micrologic, external neutral current transformer, ENCT, 60A to 100A
SKU: 172557945
Category: Circuit Breakers
Reviews (0)
Be the first to review “Circuit breaker accessory, PowerPacT H, Micrologic, external neutral current transformer, ENCT, 60A to 100A” Cancel reply
Related products
Mini CB, QO, 50 A, 1P, 120/240 V, 10 kA, Bolt on, 50Deg
Mini CB, QO, 50 A, 1P, 120/240 V, 10 kA, Bolt on, 50Deg
Circuit breaker, PowerPacT B, 125A, 1 pole, 600Y/347VAC, 18kA, I-Line, thermal magnetic, 80%, A
Circuit breaker, PowerPacT B, 125A, 1 pole, 600Y/347VAC, 18kA, I-Line, thermal magnetic, 80%, A
Circuit breaker, PowerPacT P, 800A, 3 pole, 600VAC, 25kA, I-Line, Micrologic 5.0H, 80%, ABC, modbus
Circuit breaker, PowerPacT P, 800A, 3 pole, 600VAC, 25kA, I-Line, Micrologic 5.0H, 80%, ABC, modbus
Circuit breaker frame, MasterPact MTZ2 32H2, 3200A, 100kA/440VAC 50/60Hz (Icu), 4P, drawout, without control unit
Circuit breaker frame, MasterPact MTZ2 32H2, 3200A, 100kA/440VAC 50/60Hz (Icu), 4P, drawout, without control unit
Miniature circuit breaker (MCB), Multi9 C60BP, 3P, 3A, C curve, 10kA (UL489), 10kA (IEC/EN 60947-2)
Miniature circuit breaker (MCB), Multi9 C60BP, 3P, 3A, C curve, 10kA (UL489), 10kA (IEC/EN 60947-2)
Mini circuit breaker, QOU, 20A, 2 pole, 120/240 VAC, 10kA, mounting foot
Mini circuit breaker, QOU, 20A, 2 pole, 120/240 VAC, 10kA, mounting foot
Circuit breaker, PowerPacT H, thermal magnetic, unit mount, 60A, 3 pole, 18 kA, 600 VAC, shunt trip, copper lugs, 80%
Circuit breaker, PowerPacT H, thermal magnetic, unit mount, 60A, 3 pole, 18 kA, 600 VAC, shunt trip, copper lugs, 80%
Circuit breaker, ComPact NSX250H, 70kA/415VAC, TMD trip unit 160A, 3 poles 3d
Circuit breaker, ComPact NSX250H, 70kA/415VAC, TMD trip unit 160A, 3 poles 3d
Reviews
There are no reviews yet.