Square D PowerPact family is industry leading innovation and protection for heavy duty commercial and industrial appliacations The MicroLogic Ground-Fault Module (GFM) is a UL Listed/CSA Certified circuit breaker accessory which protects equipment from damage caused by ground faults. It is an add-on module which, when connected to a PowerPact J-frame thermal-magnetic circuit breaker only, provides ground-fault sensing and ground-fault relay functions. This ground fault module with pick-up adjustment range of 150A to 250A is used with companion PowerPact j-frame breakers with current rating of 15A to 150A. A 12 Vdc shunt trip module is required in the circuit breaker. This may be field installed or factory installed when the circuit breaker is ordered with an -SN suffix. At 250 A, the ELM250JD can be used with 80% rated circuit breakers only. All GFMs are supplied for I-Line™ mounting as standard, easily convertible to unit mount by removing the I-Line bracket. The product comes as UL 1053 – Ground-fault Sensing and Relaying Equipment. Meets NEC 230.95©
Ground fault module, PowerPacT J, micrologic, Add-on ground fault modules, 40 to 200A
Ground fault module, PowerPacT J, micrologic, Add-on ground fault modules, 40 to 200A
SKU: 1341308
Category: Power Distribution
Reviews (0)
Be the first to review “Ground fault module, PowerPacT J, micrologic, Add-on ground fault modules, 40 to 200A” Cancel reply
Related products
Automatic switch, PowerPacT J, 225A, 3 pole, 600VAC, 18kA, lugs, magnetic
Automatic switch, PowerPacT J, 225A, 3 pole, 600VAC, 18kA, lugs, magnetic
EZ Meter Main Busway Tap Right Side, Neutral Back, Mn Brkr, 1200A, 3PH, 65 kA
EZ Meter Main Busway Tap Right Side, Neutral Back, Mn Brkr, 1200A, 3PH, 65 kA
Circuit breaker accessory, PowerPacT L, lug kit, compression, 600A, 3 pole, aluminum at 620A
Circuit breaker accessory, PowerPacT L, lug kit, compression, 600A, 3 pole, aluminum at 620A
Circuit breaker, PowerPacT B, 40A, 2 pole, 600Y/347VAC, 25kA, terminal nut, thermal magnetic, 80%
Circuit breaker, PowerPacT B, 40A, 2 pole, 600Y/347VAC, 25kA, terminal nut, thermal magnetic, 80%
Three Low-level MTZ2,3 CT Test Position Push in Carriage Switches
Three Low-level MTZ2,3 CT Test Position Push in Carriage Switches
Multi 9 – C60 UL489 – MCB – 3P – 13 A – D Curve – 240 V – 10 kA – ring term
Multi 9 - C60 UL489 - MCB - 3P - 13 A - D Curve - 240 V - 10 kA - ring term
Circuit Breaker Masterpact MTZ2 20H2 ANSI-2000A-4P drawout-w/o Micrologic
Circuit Breaker Masterpact MTZ2 20H2 ANSI-2000A-4P drawout-w/o Micrologic
Reviews
There are no reviews yet.