PowerPact M-frame molded case circuit breakers provide improved performance and a compact solution for applications up to 800A. They complement the existing PowerPact P- and R-frame circuit breakers and replace the traditional MA/MH circuit breakers with a smaller footprint and competitive cost. PowerPact M-frame molded case circuit breakers have built-in electronic trip unit type ET 1.0 provides better accuracy than standard thermal-magnetic trip units. The ET 1.0 trip unit cannot be field replaced, nor does it allow adjustment of the trip point setting. (It is considered an electronic equivalent of a thermal-magnetic circuit breaker.) They also have fIxed long-time and adjustable instantaneous protection (2 to 10 times nominal ampere rating) is standard. Powerpact M-Frame breakers have the same dimensions, common mounting, bussing, cabling and door cut-out as PowerPact P-frame circuit breakers. This Powerpact M,P,R shunt trip is rated at 220-240 VAC and 250 VDC. This product comes with an 18 month warranty.
Circuit breaker accessory, PowerPacT M/P/R, shunt trip, 220VAC to 240VAC, 250VDC
Circuit breaker accessory, PowerPacT M/P/R, shunt trip, 220VAC to 240VAC, 250VDC
SKU: 14791659
Category: Circuit Breakers
Reviews (0)
Be the first to review “Circuit breaker accessory, PowerPacT M/P/R, shunt trip, 220VAC to 240VAC, 250VDC” Cancel reply
Related products
Circuit breaker, PowerPacT B, 15A, 3 pole, 600Y/347VAC, 14kA, I-Line, thermal magnetic, 80%, ABC
Circuit breaker, PowerPacT B, 15A, 3 pole, 600Y/347VAC, 14kA, I-Line, thermal magnetic, 80%, ABC
Circuit breaker, ComPact NSX250H, 70kA/415VAC, TMD trip unit 160A, 3 poles 3d
Circuit breaker, ComPact NSX250H, 70kA/415VAC, TMD trip unit 160A, 3 poles 3d
Miniature circuit breaker (MCB), Multi9 C60BP, 1P, 5A, D curve, 14kA (UL489), 10kA (IEC/EN 60947-2)
Miniature circuit breaker (MCB), Multi9 C60BP, 1P, 5A, D curve, 14kA (UL489), 10kA (IEC/EN 60947-2)
Mini circuit breaker, QO, 20A, 3 pole, 240VAC, 10kA, 100mA grd fault B, bolt on mount, ring
Mini circuit breaker, QO, 20A, 3 pole, 240VAC, 10kA, 100mA grd fault B, bolt on mount, ring
Circuit breaker, PowerPacT H, 50A, 3 pole, 600VAC, 25kA, lugs, thermal magnetic, 100%
Circuit breaker, PowerPacT H, 50A, 3 pole, 600VAC, 25kA, lugs, thermal magnetic, 100%
Circuit breaker frame, MasterPact MTZ2 32H2, 3200A, 100kA/440VAC 50/60Hz (Icu), 4P, drawout, without control unit
Circuit breaker frame, MasterPact MTZ2 32H2, 3200A, 100kA/440VAC 50/60Hz (Icu), 4P, drawout, without control unit
Circuit breaker, PowerPacT H, 15A, 3 pole, 600VAC, 25kA, lugs, thermal magnetic, 80%, shunt
Circuit breaker, PowerPacT H, 15A, 3 pole, 600VAC, 25kA, lugs, thermal magnetic, 80%, shunt
Mini circuit breaker, QO, 20A, 2 pole, 120/240VAC, 10kA, bolt on, AC shunt, ring
Mini circuit breaker, QO, 20A, 2 pole, 120/240VAC, 10kA, bolt on, AC shunt, ring
Reviews
There are no reviews yet.