Powerpact B-Frame Circuit Breaker accessory, LV429426, offers proven performance, flexibility, and reliability. A time delay unit for the MN eliminates the risk of nuisance tripping due to a transient voltage dip lasting less than 200 ms for fixed delay units and up to 3 seconds for adjustable units. For shorter micro-outages, a system of capacitors provides temporary supply to the MN at V > 0.7 Vn to ensure not tripping. PowerPact B-frame ratings and types. Available in 1, 2, 3, and 4-pole unit mount construction & 1, 2, and 3-pole I-Line™ construction. Cost-effective fixed thermal-magnetic trip units from 15-125A up to 600Y/347 Vac. Interrupting ratings include D-18 kA, G-35 kA, and J-65 kA at 480 Vac. Unique I-Line construction mounts into Square D™ panelboards and switchboards. Designed to the same 1.5″ per pole widths as the legacy F-frame, simplifying substitution without blank fillers. Unit mount (aka, lug-lug) construction is 30% smaller in size with 25% more capacity than the legacy unit-mount F-frame design EverLink atented technology. EverLink lug connectors reduce the loosening of cables over time using a spring tension design. EverLink lugs are rated for bare use with fine-stranded conductors up to Class K. EverLink lugs are also available with unique integrated control wire terminals.
MN delay unit, ComPacT NSX/NSXm, fixed time delay 200ms, 48VAC 50/60Hz, spare part
MN delay unit, ComPacT NSX/NSXm, fixed time delay 200ms, 48VAC 50/60Hz, spare part
SKU: 4278514
Category: Molded Case Breakers
Reviews (0)
Be the first to review “MN delay unit, ComPacT NSX/NSXm, fixed time delay 200ms, 48VAC 50/60Hz, spare part” Cancel reply
Related products
PowerPact multistandard – J-Frame – 225 A – 100 KA – Therm-Mag trip unit
PowerPact multistandard - J-Frame - 225 A - 100 KA - Therm-Mag trip unit
J-FRAME 48/60VAC MOULDED CASE CIRCUIT BREAKER MOTOR OPERATOR
J-FRAME 48/60VAC MOULDED CASE CIRCUIT BREAKER MOTOR OPERATOR
PowerPact Q – molded case circuit breaker – 3-pole – 10 kA – 240 V – 150 A
PowerPact Q - molded case circuit breaker - 3-pole - 10 kA - 240 V - 150 A
PowerPact B Circuit Breaker, 45A, 2P, 480Y/277V AC, 35kA at 480/277 UL, I-Line
PowerPact B Circuit Breaker, 45A, 2P, 480Y/277V AC, 35kA at 480/277 UL, I-Line
Circuit breaker, PowerPact H, thermal magnetic, 15A, 3 pole, 600V, 25kA, auxiliary switch
Circuit breaker, PowerPact H, thermal magnetic, 15A, 3 pole, 600V, 25kA, auxiliary switch
Circuit breaker, PowerPact B, 30A, 1 pole, 600Y/347V AC, 14kA at 600Y/347 UL, terminal nuts
Circuit breaker, PowerPact B, 30A, 1 pole, 600Y/347V AC, 14kA at 600Y/347 UL, terminal nuts
PowerPact multistandard – L-Frame – 250 A – 25 KA – Micrologic 3.0 trip unit
PowerPact multistandard - L-Frame - 250 A - 25 KA - Micrologic 3.0 trip unit
Circuit Breaker Micrologic 2.0 Trip Unit w/Rating Plug
Circuit Breaker Micrologic 2.0 Trip Unit w/Rating Plug
Reviews
There are no reviews yet.