E-Frame Breaker are Lighting Panelboard Circuit breakers that are proven effective and reliable which provide a wide variety or robust features that are use specifically in Square D NF Panelboards. This range of breaker is ideally designed to offer superior overload and short circuit protection. All E-Frame breakers have a thermal-magnetic trip unit as well as signal indicator that will indicate when a trip has occur. Mounting bolts are used to hold these breakers in place. This E-Frame breaker is 20A, 3 pole, and has an operating voltage of 480Y/277 VAC. It also provides a 25 kA max interrupt rating at 120 VAC. This device has a hold current of 270A which is the maximum current the breaker can be held to ensure it will trip and a trip current of 875A which is the current value when the breaker is guaranteed to trip. Many accessories are available for this breaker. This one includes a shunt trip. This breaker was calibrated for 40 degrees C. This product is UL Listed as High Intensity Discharge. HACR rated.
Mini circuit breaker, E-Frame, 20A, 3 pole, 480Y/277VAC, 25kA max, bolt on, shunt trip
Mini circuit breaker, E-Frame, 20A, 3 pole, 480Y/277VAC, 25kA max, bolt on, shunt trip
SKU: 1354680
Category: Power Distribution
Reviews (0)
Be the first to review “Mini circuit breaker, E-Frame, 20A, 3 pole, 480Y/277VAC, 25kA max, bolt on, shunt trip” Cancel reply
Related products
Mini CB, QO, 25 A, 2P, 120/240 V, 10 kA, Bolt on, PL
Mini CB, QO, 25 A, 2P, 120/240 V, 10 kA, Bolt on, PL
Circuit breaker accessory, PowerPacT L, lug kit, compression, 600A, 3 pole, aluminum at 620A
Circuit breaker accessory, PowerPacT L, lug kit, compression, 600A, 3 pole, aluminum at 620A
Mini circuit breaker, QO, 15A, 1 pole, 120VAC, 10kA, plug in, dual function, pigtail
Mini circuit breaker, QO, 15A, 1 pole, 120VAC, 10kA, plug in, dual function, pigtail
Acti 9 – comb busbar – 3L+N balanced – 9 mm pitch – 12 modules – 80A
Acti 9 - comb busbar - 3L+N balanced - 9 mm pitch - 12 modules - 80A
Transformer disconnect, 1500VA, 240x480VAC primary, 120VAC secondary, with outlet, Type 1
Transformer disconnect, 1500VA, 240x480VAC primary, 120VAC secondary, with outlet, Type 1
Circuit breaker, PowerPacT B, 100A, 3 pole, 480Y/277VAC, 18kA, I-Line, thermal magnetic, 80%, ABC
Circuit breaker, PowerPacT B, 100A, 3 pole, 480Y/277VAC, 18kA, I-Line, thermal magnetic, 80%, ABC
Circuit breaker, PowerPacT B, 40A, 2 pole, 600Y/347VAC, 25kA, terminal nut, thermal magnetic, 80%
Circuit breaker, PowerPacT B, 40A, 2 pole, 600Y/347VAC, 25kA, terminal nut, thermal magnetic, 80%
Three Low-level MTZ2,3 CT Test Position Push in Carriage Switches
Three Low-level MTZ2,3 CT Test Position Push in Carriage Switches
Reviews
There are no reviews yet.