PowerPacT J-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT J-Frame circuit breakers are available with either thermal magnetic or MicroLogic electronic trip protection units. This PowerPacT J-Frame circuit breaker provides Micrologic Standard with a 3.2S trip unit and an LSI function with a breaking capacity of 65kA at 480VAC. All PowerPacT J-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT J circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. This breaker has lugs on both the line and load sides. This PowerPacT J, 250A, 3 pole, circuit breaker has a breaking capacity of 65kA at 480VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT J circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
Circuit breaker, PowerPacT J, 250A, 3 pole, 480VAC, 65kA, lugs, Micrologic 3.2S, 80%, mission critical
Circuit breaker, PowerPacT J, 250A, 3 pole, 480VAC, 65kA, lugs, Micrologic 3.2S, 80%, mission critical
SKU: 16797571
Category: Power Distribution
Reviews (0)
Be the first to review “Circuit breaker, PowerPacT J, 250A, 3 pole, 480VAC, 65kA, lugs, Micrologic 3.2S, 80%, mission critical” Cancel reply
Related products
Transformer disconnect, 1500VA, 240x480VAC primary, 120VAC secondary, with outlet, Type 1
Transformer disconnect, 1500VA, 240x480VAC primary, 120VAC secondary, with outlet, Type 1
Acti 9 – comb busbar – 3L+N balanced – 9 mm pitch – 12 modules – 80A
Acti 9 - comb busbar - 3L+N balanced - 9 mm pitch - 12 modules - 80A
Tap box, I-Line Busway, plug-in, 100A, 3 phase, 4 wire, 600VAC
Tap box, I-Line Busway, plug-in, 100A, 3 phase, 4 wire, 600VAC
Circuit breaker, PowerPacT L, 250A, 3 pole, 600VAC, 50kA, lugs, MicroLogic 3.3S, 80%
Circuit breaker, PowerPacT L, 250A, 3 pole, 600VAC, 50kA, lugs, MicroLogic 3.3S, 80%
Multi 9 – C60 UL489 – MCB – 3P – 4 A – D Curve – 480Y/277 V – 10 kA – ring term
Multi 9 - C60 UL489 - MCB - 3P - 4 A - D Curve - 480Y/277 V - 10 kA - ring term
Transformer, Type T, industrial control, 75VA, 1 phase, 208V primary, 120V secondary, 55C rise
Transformer, Type T, industrial control, 75VA, 1 phase, 208V primary, 120V secondary, 55C rise
Circuit breaker accessory, PowerPacT L, lug kit, compression, 600A, 3 pole, aluminum at 620A
Circuit breaker accessory, PowerPacT L, lug kit, compression, 600A, 3 pole, aluminum at 620A