Square D PowerPact family is industry leading innovation and protection for heavy duty commercial and industrial appliacations The MicroLogic Ground-Fault Module (GFM) is a UL Listed/CSA Certified circuit breaker accessory which protects equipment from damage caused by ground faults. It is an add-on module which, when connected to a PowerPact J-frame thermal-magnetic circuit breaker only, provides ground-fault sensing and ground-fault relay functions. This ground fault module with pick-up adjustment range of 150A to 250A is used with companion PowerPact j-frame breakers with current rating of 15A to 150A. A 12 Vdc shunt trip module is required in the circuit breaker. This may be field installed or factory installed when the circuit breaker is ordered with an -SN suffix. At 250 A, the ELM250JD can be used with 80% rated circuit breakers only. All GFMs are supplied for I-Line™ mounting as standard, easily convertible to unit mount by removing the I-Line bracket. The product comes as UL 1053 – Ground-fault Sensing and Relaying Equipment. Meets NEC 230.95©
Ground fault module, PowerPacT J, micrologic, Add-on ground fault modules, 40 to 200A
Ground fault module, PowerPacT J, micrologic, Add-on ground fault modules, 40 to 200A
SKU: 1341308
Category: Power Distribution
Reviews (0)
Be the first to review “Ground fault module, PowerPacT J, micrologic, Add-on ground fault modules, 40 to 200A” Cancel reply
Related products
Circuit breaker, PowerPacT B, 70A, 2 pole, 600Y/347VAC, 14kA, lugs, thermal magnetic, 80%
Circuit breaker, PowerPacT B, 70A, 2 pole, 600Y/347VAC, 14kA, lugs, thermal magnetic, 80%
Circuit breaker, PowerPacT L, 250A, 3 pole, 600VAC, 50kA, lugs, MicroLogic 3.3S, 80%
Circuit breaker, PowerPacT L, 250A, 3 pole, 600VAC, 50kA, lugs, MicroLogic 3.3S, 80%
Circuit Breaker Masterpact MTZ2 20H2 ANSI-2000A-4P drawout-w/o Micrologic
Circuit Breaker Masterpact MTZ2 20H2 ANSI-2000A-4P drawout-w/o Micrologic
Transformer, Type T, industrial control, 75VA, 1 phase, 208V primary, 120V secondary, 55C rise
Transformer, Type T, industrial control, 75VA, 1 phase, 208V primary, 120V secondary, 55C rise
Circuit breaker, PowerPacT R, 1600A, 3 pole, 600VAC, 50kA, busbar, Micrologic 5.0H, 80%, modbus
Circuit breaker, PowerPacT R, 1600A, 3 pole, 600VAC, 50kA, busbar, Micrologic 5.0H, 80%, modbus
Tap box, I-Line Busway, plug-in, 100A, 3 phase, 4 wire, 600VAC
Tap box, I-Line Busway, plug-in, 100A, 3 phase, 4 wire, 600VAC
Transformer disconnect, 1500VA, 240x480VAC primary, 120VAC secondary, with outlet, Type 1
Transformer disconnect, 1500VA, 240x480VAC primary, 120VAC secondary, with outlet, Type 1

Reviews
There are no reviews yet.