This Multi 9 C60 UL489 is a low voltage miniature circuit breaker (MCB). It is a 3P circuit-breaker with 3 protected poles, 10A rated current and C tripping curve. It can be mounted on DIN rail for modular installation. As circuit-breaker, its breaking capacity, according to IEC/EN 60947-2, is 10kA at 277VAC and 400VAC. This circuit-breaker offers a protection of circuits against overcurrent according to UL 489. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. It becomes IP40 once in modular enclosure. its fast closing mechanism improves its service life. The trip-free mechanism allows the contacts to not be held in the on position when the device is tripped automatically. The green mechanical indication guarantees the physical opening of the contacts to allow downstream maintenance.
Multi 9 – C60 UL489 – MCB – 3P – 10 A – C Curve – 480Y/277 V – 10 kA – tunnel t
Multi 9 – C60 UL489 – MCB – 3P – 10 A – C Curve – 480Y/277 V – 10 kA – tunnel t
SKU: 1280563
Category: Power Distribution
Reviews (0)
Be the first to review “Multi 9 – C60 UL489 – MCB – 3P – 10 A – C Curve – 480Y/277 V – 10 kA – tunnel t” Cancel reply
Related products
Ring tongue terminal connections kit – for C60 upstream/downstream – set of 2
Ring tongue terminal connections kit - for C60 upstream/downstream - set of 2
Circuit breaker, PowerPacT H, 45A, 3 pole, 600VAC, 18kA, I-Line, thermal magnetic, 80%, CBA
Circuit breaker, PowerPacT H, 45A, 3 pole, 600VAC, 18kA, I-Line, thermal magnetic, 80%, CBA
Transformer, Type TF, industrial control, 100 VA, 120/240 VAC primary / 24 VAC secondary, 1 phase, 50/60 Hz, 55 °C rise
Transformer, Type TF, industrial control, 100 VA, 120/240 VAC primary / 24 VAC secondary, 1 phase, 50/60 Hz, 55 °C rise
Multi 9 – C60 UL489 – MCB – 3P – 4 A – D Curve – 480Y/277 V – 10 kA – ring term
Multi 9 - C60 UL489 - MCB - 3P - 4 A - D Curve - 480Y/277 V - 10 kA - ring term
Circuit breaker frame, MasterPact MTZ2 12H1, 1250A, 66kA/440VAC 50/60Hz (Icu), 3P, fixed, without control unit
Circuit breaker frame, MasterPact MTZ2 12H1, 1250A, 66kA/440VAC 50/60Hz (Icu), 3P, fixed, without control unit
Circuit breaker, PowerPacT P, 400A, 3 pole, 600VAC, 25kA, I-Line, Micrologic 5.0H, 80%, ABC, modbus
Circuit breaker, PowerPacT P, 400A, 3 pole, 600VAC, 25kA, I-Line, Micrologic 5.0H, 80%, ABC, modbus
Transformer, Type T, industrial control, 75VA, 1 phase, 208V primary, 120V secondary, 55C rise
Transformer, Type T, industrial control, 75VA, 1 phase, 208V primary, 120V secondary, 55C rise
Three Low-level MTZ2,3 CT Test Position Push in Carriage Switches
Three Low-level MTZ2,3 CT Test Position Push in Carriage Switches