This XCKP standard format (CENELEC EN 50047) limit switch has a metal plunger head and a plastic body. The limit switch is a device that converts a mechanical motion into an electrical control signal. This limit switch has a double insulated thermoplastic body, a modular design allowing easier maintenance and a compact CENELEC EN50047 format. It has 1 normally closed and 1 normally open, form Zb, snap action contacts. It has a rated operational current of 3A at 240VAC (A300) (AC-15), 0.27A at 250VDC (Q300)(DC13) and a conventional enclosed thermal current of 5A. Its mechanical durability is 15 million operating cycles and electrical durability is 5 million operating cycles. It is furnished with screw clamp terminals for electrical connection. It has a metal plunger head that supports vertical approach from one direction. It is an IP66, IP67 and NEMA 1/2/4/6/6P/12/13 rated product. Limit switch has an M12 4 pin male connector. This limit switch has dimensions of 1.22inch (Width) x 1.18inch (Depth) x 2.56inch (Height) and weighs 0.22 lbs. It complies with UL 508, CSA C22.2 No.14, EN/IEC 60947.-5-1, and EN/IEC 60204-1 standards. Limit switch has a UL Listed, CSA Certified and CCC certifications. Limit switches for contact sensing of inflexible objects. An offer of positive opening snap action contacts for a simpler and safer machine design. IEC standard format limit switches consist of products designed according to EN 50047, EN 50041 as well as popular XCM and XCKM limit switches ranges.
Limit switch, Limit switches XC Standard, XCKP, metal end plunger, 1NC+1 NO, snap
Limit switch, Limit switches XC Standard, XCKP, metal end plunger, 1NC+1 NO, snap
SKU: 4324606
Category: Sensors & Switches
Reviews (0)
Be the first to review “Limit switch, Limit switches XC Standard, XCKP, metal end plunger, 1NC+1 NO, snap” Cancel reply
Related products
Pressure switch 9012G – adjustable scale – 2 thresholds – 1.5 to 75 psig
Pressure switch 9012G - adjustable scale - 2 thresholds - 1.5 to 75 psig
Coded magnetic switch, Telemecanique Safety switches XCS, XCSDMP, 1 NC + 1 NO, staggered, 10 m
Coded magnetic switch, Telemecanique Safety switches XCS, XCSDMP, 1 NC + 1 NO, staggered, 10 m
9007MS limit switch – cross roller plunger – booted – 12′ bottom cable
9007MS limit switch - cross roller plunger - booted - 12' bottom cable
Limit switch lever, Limit switches XC Standard, ZCY, steel roller
Limit switch lever, Limit switches XC Standard, ZCY, steel roller
pressure switch XMLC 20 bar – adjustable scale 2 thresholds – 2 C/O
pressure switch XMLC 20 bar - adjustable scale 2 thresholds - 2 C/O
Closed tank – NEMA 7/9 – screw-in bushing – 2 NC DPST-DB contacts
Closed tank - NEMA 7/9 - screw-in bushing - 2 NC DPST-DB contacts
Reviews
There are no reviews yet.