These TeSys VLS disconnect switches are for integration into control systems in applications like material handling, HVAC, pumping, solar energy, mining and many more. This family of disconnect switches has switches ranging from 16A to 125A. The 16A, 25A, 32A, 40A and 63A disconnect switches are UL508 motor disconnect switches rated. The 30A, 63A, 80A, 100A and 125A disconnect switches are UL98 non fusible disconnect switch rated. This fourth pole adder can be added to a VLS3P016R1, VLS3P025R1, VLS3P032R1 or VLS3P040R1 DIN rail mount switch. This fourth pole adder for DIN rail mounted devices can be mounted on the right or left hand side. This simultaneous closing adder pole has one normally open contact The operational voltage of this fourth pole adder module is 600 Vac 50/60 Hz. This fourth pole adder module has a 40 A current rating. The screw clamp terminals will accept 18 AWG to 6 AWG wire. Fourth pole adder is 3.07 inches tall, 0.47 inches wide and 1.72 inches deep. It weighs 0.09 lbs. This fourth pole adder block is cULus Listed and meets IEC 60947-3 requirements.
Disconnect switch, TeSys VLS, additional pole, 40A, for 16A to 40A switch, size 1, DIN rail
Disconnect switch, TeSys VLS, additional pole, 40A, for 16A to 40A switch, size 1, DIN rail
SKU: 4278771
Category: Disconnect Switches
Reviews (0)
Be the first to review “Disconnect switch, TeSys VLS, additional pole, 40A, for 16A to 40A switch, size 1, DIN rail” Cancel reply
Related products
Auxiliary contacts, TeSys GS, 1 NC, early break, front mounting, for GS2 with front/side handle
Auxiliary contacts, TeSys GS, 1 NC, early break, front mounting, for GS2 with front/side handle
Disconnect switch, TeSys VLS, adapter for VLSH3S7RD and VLSH3S7BD handles, for 7mm shaft, for VLS3P030R2 to VLS3P125R2
Disconnect switch, TeSys VLS, adapter for VLSH3S7RD and VLSH3S7BD handles, for 7mm shaft, for VLS3P030R2 to VLS3P125R2
Fuse carrier, TeSys DF, 2P, 125A, 690VAC, fuse size 22x58mm
Fuse carrier, TeSys DF, 2P, 125A, 690VAC, fuse size 22x58mm
Disconnect switch, TeSys VLS, body switch, 32A, 20HP at 480VAC, UL508, three phase, 5kA SCCR, size 1, DIN rail mount
Disconnect switch, TeSys VLS, body switch, 32A, 20HP at 480VAC, UL508, three phase, 5kA SCCR, size 1, DIN rail mount
Switch unit, QMB fusible panelboards, 800A, 15 inch, 3 pole, 500HP @ 600VAC max
Switch unit, QMB fusible panelboards, 800A, 15 inch, 3 pole, 500HP @ 600VAC max
Fuse carrier, TeSys DF, 1P Neutral, 50A, 690VAC, fuse size 14x51mm, with tubular link
Fuse carrier, TeSys DF, 1P Neutral, 50A, 690VAC, fuse size 14x51mm, with tubular link
Reviews
There are no reviews yet.