PowerPacT L-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT L-Frame circuit breakers are available with electronic trip units. All PowerPacT L-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT L circuit breakers are available in 3 and 4-pole unit mount, I-Line, and drawout constructions. This PowerPacT L, 250A, 3 pole, circuit breaker has an interrupting rating of 50kA at 600VAC. This circuit breaker provides MicroLogic Standard with a 3.3S trip unit and an LSI function. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. PowerPacT L circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
Circuit breaker, PowerPacT L, 250A, 3 pole, 600VAC, 50kA, I-Line, MicroLogic 3.3S, 80%, ABC
Circuit breaker, PowerPacT L, 250A, 3 pole, 600VAC, 50kA, I-Line, MicroLogic 3.3S, 80%, ABC
SKU: 16946121
Category: Power Distribution
Reviews (0)
Be the first to review “Circuit breaker, PowerPacT L, 250A, 3 pole, 600VAC, 50kA, I-Line, MicroLogic 3.3S, 80%, ABC” Cancel reply
Related products
Automatic switch, PowerPacT J, 225A, 3 pole, 600VAC, 18kA, lugs, magnetic
Automatic switch, PowerPacT J, 225A, 3 pole, 600VAC, 18kA, lugs, magnetic
Acti 9 – comb busbar – 3L+N balanced – 9 mm pitch – 12 modules – 80A
Acti 9 - comb busbar - 3L+N balanced - 9 mm pitch - 12 modules - 80A
Multi 9 – C60 UL489 – MCB – 3P – 13 A – D Curve – 240 V – 10 kA – ring term
Multi 9 - C60 UL489 - MCB - 3P - 13 A - D Curve - 240 V - 10 kA - ring term
Circuit breaker, PowerPacT H, 110A, 2 pole, 600VAC, 14kA, I-Line, thermal magnetic, 80%, CB
Circuit breaker, PowerPacT H, 110A, 2 pole, 600VAC, 14kA, I-Line, thermal magnetic, 80%, CB
Circuit breaker, PowerPacT B, 40A, 2 pole, 600Y/347VAC, 25kA, terminal nut, thermal magnetic, 80%
Circuit breaker, PowerPacT B, 40A, 2 pole, 600Y/347VAC, 25kA, terminal nut, thermal magnetic, 80%
Tap box, I-Line Busway, plug-in, 100A, 3 phase, 4 wire, 600VAC
Tap box, I-Line Busway, plug-in, 100A, 3 phase, 4 wire, 600VAC
Mini CB, QO, 25 A, 2P, 120/240 V, 10 kA, Bolt on, PL
Mini CB, QO, 25 A, 2P, 120/240 V, 10 kA, Bolt on, PL
Three Low-level MTZ2,3 CT Test Position Push in Carriage Switches
Three Low-level MTZ2,3 CT Test Position Push in Carriage Switches
Reviews
There are no reviews yet.