Type S nonreversing fusible combination starters are for motor control applications. Combination starters combine the requirements for motor overload and short circuit protection into one package. NEMA Size 2 starters have ratings of up to 10 HP at 200 and 240 VAC poly phase. Combination starter has 60 ampere Class H and K fuse clips. This 3 pole starter is for poly phase applications. Combination starters are available with a wide variety of replaceable coil voltages. Starter has a 110/120 VAC 50/60 Hz operating coil wired for separate control. This nonreversing NEMA combination starter has a Motor Logic solid state overload relay to detect over current conditions. A painted sheet steel NEMA 3R/12 dusttight enclosure is used to protect this starter. Enclosure is 27.75 inches tall, 10.5 inches wide and 9.59 inches deep. A wide variety of accessories are available for Type S starters. This combination starters is supplied with a HOA selector switch, a red and green pilot light, auxiliary contacts and an interlock on disconnect. Type S combination starters are UL listed and CSA certified.
NEMA combination starter, Type S, 60A fusible disconnect, Size 2, 45A, 10HP at 240VAC, 3 phase, 3 pole, Motor Logic SSOLR, 120VAC coil, NEMA 12
NEMA combination starter, Type S, 60A fusible disconnect, Size 2, 45A, 10HP at 240VAC, 3 phase, 3 pole, Motor Logic SSOLR, 120VAC coil, NEMA 12
SKU: 172547716
Category: Automation & Control
Reviews (0)
Be the first to review “NEMA combination starter, Type S, 60A fusible disconnect, Size 2, 45A, 10HP at 240VAC, 3 phase, 3 pole, Motor Logic SSOLR, 120VAC coil, NEMA 12” Cancel reply
Related products
Blue light block with body/fixing collar with integral LED 24V 2NO
Blue light block with body/fixing collar with integral LED 24V 2NO
Inductive proximity sensors XS, inductive sensor XS6 M30, L74mm, brass, Sn22mm, 24…240VAC/DC, 1/2″
Inductive proximity sensors XS, inductive sensor XS6 M30, L74mm, brass, Sn22mm, 24...240VAC/DC, 1/2"
TeSys Deca thermal overload relays – 23…32 A – class 10A
TeSys Deca thermal overload relays - 23...32 A - class 10A
Contactor, Definite Purpose, 30A, 2 pole, 110/120VAC 50/60Hz coil, open
Contactor, Definite Purpose, 30A, 2 pole, 110/120VAC 50/60Hz coil, open
Disconnect Switch, TeSys LK4 Non fusible, 50hp at 600VAC, 3 pole, max 100A rated, plate mount
Disconnect Switch, TeSys LK4 Non fusible, 50hp at 600VAC, 3 pole, max 100A rated, plate mount
Harmony XB5, Antimicrobial Flush mounted push button head, plastic, projecting, black, Ø30, spring return, unmarked, dark grey bezel
Harmony XB5, Antimicrobial Flush mounted push button head, plastic, projecting, black, Ø30, spring return, unmarked, dark grey bezel