QO generator panels are for the manual transfer from utility to generator power. QO generator panels are for back-up power applications. This sub-panel connects directly to the main load center and provides four single pole spaces that will accommodate up to eight circuits dedicated for back-up power. This QO generator panel uses two factory installed, two pole QO circuit breakers. One is fed by the utility, while the second circuit breaker is back-fed to the back-up power source, such as a generator. Power source switching is easy. Simply turn the main power breaker to the “OFF” position and then turn the generator fed breaker to the “ON” position. A factory installed mechanical interlock prevents both main breakers being in the “ON” position at the same time. This manual transfer equipment kit is used secure two 2 pole circuit breakers to left side of interior when used as back-fed mains. A QO2DTI kit is included for back-up power supply applications. This kit is used on Series S01 and S02 100A to 125A single phase convertible main load centers.
Load center accessory, QO, manual transfer kit, 1 phase, 100A to 125A, for convertible main load centers, left side
Load center accessory, QO, manual transfer kit, 1 phase, 100A to 125A, for convertible main load centers, left side
SKU: 172549198
Category: Power Distribution
Reviews (0)
Be the first to review “Load center accessory, QO, manual transfer kit, 1 phase, 100A to 125A, for convertible main load centers, left side” Cancel reply
Related products
Transformer, Type T, industrial control, 75VA, 1 phase, 208V primary, 120V secondary, 55C rise
Transformer, Type T, industrial control, 75VA, 1 phase, 208V primary, 120V secondary, 55C rise
QOU Miniature Circuit Breaker, 20A, 2P, 120/240V, 10kA, Aux Switch
QOU Miniature Circuit Breaker, 20A, 2P, 120/240V, 10kA, Aux Switch
Transformer disconnect, 1500VA, 240x480VAC primary, 120VAC secondary, with outlet, Type 1
Transformer disconnect, 1500VA, 240x480VAC primary, 120VAC secondary, with outlet, Type 1
Circuit breaker, PowerPacT L, 250A, 3 pole, 600VAC, 50kA, lugs, MicroLogic 3.3S, 80%
Circuit breaker, PowerPacT L, 250A, 3 pole, 600VAC, 50kA, lugs, MicroLogic 3.3S, 80%
Circuit breaker, PowerPacT P, 1000A, 3 pole, 600VAC, 25kA, lugs, Micrologic 3.0A, 80%
Circuit breaker, PowerPacT P, 1000A, 3 pole, 600VAC, 25kA, lugs, Micrologic 3.0A, 80%
Circuit breaker, PowerPacT H, 110A, 2 pole, 600VAC, 14kA, I-Line, thermal magnetic, 80%, CB
Circuit breaker, PowerPacT H, 110A, 2 pole, 600VAC, 14kA, I-Line, thermal magnetic, 80%, CB
Circuit breaker, PowerPacT R, 1600A, 3 pole, 600VAC, 50kA, busbar, Micrologic 5.0H, 80%, modbus
Circuit breaker, PowerPacT R, 1600A, 3 pole, 600VAC, 50kA, busbar, Micrologic 5.0H, 80%, modbus
Circuit breaker accessory, PowerPacT J, rear connection kit, 3 pole, mixed, 4x short, 2x covers
Circuit breaker accessory, PowerPacT J, rear connection kit, 3 pole, mixed, 4x short, 2x covers

Reviews
There are no reviews yet.