PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 25kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT H I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This breaker has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT H, 90A, 2 pole, circuit breaker has a breaking capacity of 25kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an AC phase connection. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
Circuit breaker, PowerPacT H, 90A, 2 pole, 600VAC, 25kA, I-Line, thermal magnetic, 80%, AC
Circuit breaker, PowerPacT H, 90A, 2 pole, 600VAC, 25kA, I-Line, thermal magnetic, 80%, AC
SKU: 172556292
Category: Circuit Breakers
Reviews (0)
Be the first to review “Circuit breaker, PowerPacT H, 90A, 2 pole, 600VAC, 25kA, I-Line, thermal magnetic, 80%, AC” Cancel reply
Related products
Mini circuit breaker, QOU, 20A, 2 pole, 120/240 VAC, 10kA, mounting foot
Mini circuit breaker, QOU, 20A, 2 pole, 120/240 VAC, 10kA, mounting foot
Motor circuit protector, PowerPacT H, unit mount, 30A, 3 pole, 25kA, 600 VAC, auxiliary switch, copper lugs, 80% rated
Motor circuit protector, PowerPacT H, unit mount, 30A, 3 pole, 25kA, 600 VAC, auxiliary switch, copper lugs, 80% rated
Second MX voltage release, MasterPact MTZ1 drawout, remote tripping, 277VAC 50/60Hz
Second MX voltage release, MasterPact MTZ1 drawout, remote tripping, 277VAC 50/60Hz
Circuit breaker, PowerPacT B, 125A, 1 pole, 600Y/347VAC, 14kA, I-Line, thermal magnetic, 80%, C
Circuit breaker, PowerPacT B, 125A, 1 pole, 600Y/347VAC, 14kA, I-Line, thermal magnetic, 80%, C
Circuit breaker, PowerPacT H, 50A, 3 pole, 600VAC, 25kA, lugs, thermal magnetic, 100%
Circuit breaker, PowerPacT H, 50A, 3 pole, 600VAC, 25kA, lugs, thermal magnetic, 100%
Circuit breaker frame, MasterPact MTZ2 32H2, 3200A, 100kA/440VAC 50/60Hz (Icu), 4P, drawout, without control unit
Circuit breaker frame, MasterPact MTZ2 32H2, 3200A, 100kA/440VAC 50/60Hz (Icu), 4P, drawout, without control unit
Circuit breaker, PowerPacT B, 15A, 3 pole, 600Y/347VAC, 14kA, I-Line, thermal magnetic, 80%, ABC
Circuit breaker, PowerPacT B, 15A, 3 pole, 600Y/347VAC, 14kA, I-Line, thermal magnetic, 80%, ABC
Circuit breaker, PowerPacT B, 70A, 4 pole, 600Y/347VAC, 18kA, lugs, thermal magnetic, 80%, control wire ON end
Circuit breaker, PowerPacT B, 70A, 4 pole, 600Y/347VAC, 18kA, lugs, thermal magnetic, 80%, control wire ON end
Reviews
There are no reviews yet.