Type S NEMA motor starters are used for full voltage starting and stopping of AC squirrel cage motors. Type S motor starters have ratings up to 810 amperes. This 3 pole NEMA Size 0 non-reversing starter has an 18 ampere rating. NEMA Size 0 motor starters have 3 phase ratings of 3 HP at 200 and 230 VAC and 5 HP at 460 and 575 VAC. This non-reversing NEMA motor starter has an adapted bimetallic overload relay to sense over current conditions. This NEMA starter has a 65 kA maximum SCCR (Short Circuit Current Rating) per UL508A when protected by an appropriate circuit breaker or fuse. Type S motor starters are available with replaceable coils in a wide variety of voltages. This starter has a 110/120 VAC 50/60 Hz operating coil wired for separate control. A painted sheet steel NEMA 1 general purpose enclosure is used to protect this starter. Enclosure is 10.00 inches tall, 6.00 inches wide and 5.56 inches deep. A wide variety of accessories are available for Type S starters. Type S non-reversing NEMA motor starters are UL listed and CSA certified.
NEMA Motor Starter, Type S, nonreversing, Size 0, 18A, 5 HP at 460 VAC, up to 65 kA SCCR, 3 phase, 3 pole, bimetal, 120 VAC coil, NEMA 1
NEMA Motor Starter, Type S, nonreversing, Size 0, 18A, 5 HP at 460 VAC, up to 65 kA SCCR, 3 phase, 3 pole, bimetal, 120 VAC coil, NEMA 1
	
			
		SKU: 8938412
	
	Category: Starters & Contactors
	
	
							
											
				Reviews (0)
				
					
						
							
	
			
					
		
	
	
						
					
				
			
					
		Be the first to review “NEMA Motor Starter, Type S, nonreversing, Size 0, 18A, 5 HP at 460 VAC, up to 65 kA SCCR, 3 phase, 3 pole, bimetal, 120 VAC coil, NEMA 1” Cancel reply	
				Related products
IEC contactor, TeSys Deca, nonreversing, 32A, 20HP at 480VAC, 3 phase, 3 pole, 3 NO, 24VDC coil, open style
					IEC contactor, TeSys Deca, nonreversing, 32A, 20HP at 480VAC, 3 phase, 3 pole, 3 NO, 24VDC coil, open style				
			Non-Reversing Contactor, Size 2, 2-Pole, Open Style +Options
					Non-Reversing Contactor, Size 2, 2-Pole, Open Style +Options				
			TeSys F – specific contactor coil – 110 V AC 40…400 Hz low consumption
					TeSys F - specific contactor coil - 110 V AC 40...400 Hz low consumption				
			TeSys D contactor – 4P(4 NO) – AC-1 – <= 440 V 60 A – 12 V DC standard coil
					TeSys D contactor - 4P(4 NO) - AC-1 - <= 440 V 60 A - 12 V DC standard coil				
			Contactor, Type S, combination lighting, electrically held, 30A, 3 pole, breaker, 440/480 VAC 50/60 Hz coil, NEMA 1
					Contactor, Type S, combination lighting, electrically held, 30A, 3 pole, breaker, 440/480 VAC 50/60 Hz coil, NEMA 1				
			Contactor, Type L, multipole lighting, mechanically held, 30A, 10 pole, 600 V, 110/120 VAC 50/60 Hz coil, open style
					Contactor, Type L, multipole lighting, mechanically held, 30A, 10 pole, 600 V, 110/120 VAC 50/60 Hz coil, open style				
			Panelboard lighting contactor auxiliary contact module, top assembly, 1NO-1NC
					Panelboard lighting contactor auxiliary contact module, top assembly, 1NO-1NC				
			Contactor, Type S, multipole lighting, electrically held, 400A, 3 pole, 550/600 V 50/60 Hz coil, open style
					Contactor, Type S, multipole lighting, electrically held, 400A, 3 pole, 550/600 V 50/60 Hz coil, open style				
			 
		
 
								 
								 
		 
		 
		 
		 
		 
		
Reviews
There are no reviews yet.