Homeline miniature circuit breakers are engineered and designed for fast installation and superior circuit protection. Homeline circuit breakers are designed to plug into Homeline load centers to provide circuit protection. This circuit breaker provides standard circuit protection and is HACR rated. This 2 pole circuit breaker with plug in mounting is rated 50A at 120/240 VAC. HOM breakers provide 10 kA breaking capacity. This Homeline circuit breaker has Class B equipment protection ground fault protection. This Homeline circuit breakers has 30mA equipment ground fault protection. The electrical connection is a clamp terminal that will accept 1 wire. The clamp terminal will accept a wire range of 14 AWG to 8 AWG copper or aluminum wire. HOM Homeline miniature circuit breakers are UL Listed.
Mini circuit breaker, Homeline, 50A, 2 pole, 120/240VAC, 10kA AIR, ground fault class B, plug in, UL
Mini circuit breaker, Homeline, 50A, 2 pole, 120/240VAC, 10kA AIR, ground fault class B, plug in, UL
SKU: 15214649
Category: Power Distribution
Reviews (0)
Be the first to review “Mini circuit breaker, Homeline, 50A, 2 pole, 120/240VAC, 10kA AIR, ground fault class B, plug in, UL” Cancel reply
Related products
Circuit breaker, PowerPacT B, 100A, 3 pole, 480Y/277VAC, 18kA, I-Line, thermal magnetic, 80%, ABC
Circuit breaker, PowerPacT B, 100A, 3 pole, 480Y/277VAC, 18kA, I-Line, thermal magnetic, 80%, ABC
Circuit breaker, PowerPacT P, 1000A, 3 pole, 600VAC, 25kA, lugs, Micrologic 3.0A, 80%
Circuit breaker, PowerPacT P, 1000A, 3 pole, 600VAC, 25kA, lugs, Micrologic 3.0A, 80%
Three Low-level MTZ2,3 CT Test Position Push in Carriage Switches
Three Low-level MTZ2,3 CT Test Position Push in Carriage Switches
Transformer, Type T, industrial control, 75VA, 1 phase, 208V primary, 120V secondary, 55C rise
Transformer, Type T, industrial control, 75VA, 1 phase, 208V primary, 120V secondary, 55C rise
Circuit Breaker Masterpact MTZ2 20H2 ANSI-2000A-4P drawout-w/o Micrologic
Circuit Breaker Masterpact MTZ2 20H2 ANSI-2000A-4P drawout-w/o Micrologic
Tap box, I-Line Busway, plug-in, 100A, 3 phase, 4 wire, 600VAC
Tap box, I-Line Busway, plug-in, 100A, 3 phase, 4 wire, 600VAC
Circuit breaker, PowerPacT H, 80A, 3 pole, 600VAC, 25kA, lugs, thermal magnetic, 80%, shunt, control wire both
Circuit breaker, PowerPacT H, 80A, 3 pole, 600VAC, 25kA, lugs, thermal magnetic, 80%, shunt, control wire both
Multi 9 – C60 UL489 – MCB – 3P – 4 A – D Curve – 480Y/277 V – 10 kA – ring term
Multi 9 - C60 UL489 - MCB - 3P - 4 A - D Curve - 480Y/277 V - 10 kA - ring term
Reviews
There are no reviews yet.