The PowerPact™ H-, J-, and L-frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. L-frame circuit breakers are available with MICROLOGIC electronic trip units only. The amperage ratings of the thermal trip elements are calibrated at 104°F (40°C) free air ambient temperature. Circuit breakers rated for 100% operation are available but require specially-designed enclosures and 194°F (90°C) rated wire. Devices with the MICROLOGIC electronic trip unit provide adjustable protection settings for greater system flexibility In addition to electronic protection, MICROLOGIC trip units allow users to monitor both energy and power. PowerPact H-, J-, and L-frame circuit breakers offer high performance and a wide range of interchangeable trip units to protect most applications. Electronic trip units provide highly accurate protection with wide setting ranges and can integrate measurement, metering and communication functions. This PowerPact circuit breaker, is a 300A, and is a 3-pole,with a breaking capacity of 35kA@480VAC rated operatiuonal voltage. With a magnetic hold current of 1500A and a magnetic tripping current of 3000A. This breaker has a thermal-magnetic trip unit technology. This unit mount breaker copmplies to UL, CSA standards. Dinemsions for this product are 12.5 in (H), 6 in (W), 4 in (D), and an ambient temperature rating of 40 °C.
Circuit breaker, LH, I-Line mount, 300A, 3 pole, 25kA, 600VAC, thermal magnetic
Circuit breaker, LH, I-Line mount, 300A, 3 pole, 25kA, 600VAC, thermal magnetic
SKU: 1283962
Category: Power Distribution
Reviews (0)
Be the first to review “Circuit breaker, LH, I-Line mount, 300A, 3 pole, 25kA, 600VAC, thermal magnetic” Cancel reply
Related products
Mini CB, QO, 25 A, 2P, 120/240 V, 10 kA, Bolt on, PL
Mini CB, QO, 25 A, 2P, 120/240 V, 10 kA, Bolt on, PL
Transformer disconnect, 1500VA, 240x480VAC primary, 120VAC secondary, with outlet, Type 1
Transformer disconnect, 1500VA, 240x480VAC primary, 120VAC secondary, with outlet, Type 1
Tap box, I-Line Busway, plug-in, 100A, 3 phase, 4 wire, 600VAC
Tap box, I-Line Busway, plug-in, 100A, 3 phase, 4 wire, 600VAC
Circuit breaker accessory, PowerPacT L, lug kit, compression, 600A, 3 pole, aluminum at 620A
Circuit breaker accessory, PowerPacT L, lug kit, compression, 600A, 3 pole, aluminum at 620A
Circuit breaker, PowerPacT H, 110A, 2 pole, 600VAC, 14kA, I-Line, thermal magnetic, 80%, CB
Circuit breaker, PowerPacT H, 110A, 2 pole, 600VAC, 14kA, I-Line, thermal magnetic, 80%, CB
EZ Meter Main Busway Tap Right Side, Neutral Back, Mn Brkr, 1200A, 3PH, 65 kA
EZ Meter Main Busway Tap Right Side, Neutral Back, Mn Brkr, 1200A, 3PH, 65 kA
Circuit breaker, PowerPacT B, 100A, 3 pole, 480Y/277VAC, 18kA, I-Line, thermal magnetic, 80%, ABC
Circuit breaker, PowerPacT B, 100A, 3 pole, 480Y/277VAC, 18kA, I-Line, thermal magnetic, 80%, ABC
Reviews
There are no reviews yet.