PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn’t have that interchangeability. This circuit breaker has a Micrologic Interchangeable Standard with a 3.0 trip unit and an LI function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT P, 400A, 3 pole, circuit breaker has an interrupting rating of 25kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
Circuit breaker, PowerPacT P, 400A, 3 pole, 600VAC, 25kA, I-Line, Micrologic 3.0, 80%, ABC
Circuit breaker, PowerPacT P, 400A, 3 pole, 600VAC, 25kA, I-Line, Micrologic 3.0, 80%, ABC
SKU: 16937954
Category: Power Distribution
Reviews (0)
Be the first to review “Circuit breaker, PowerPacT P, 400A, 3 pole, 600VAC, 25kA, I-Line, Micrologic 3.0, 80%, ABC” Cancel reply
Related products
Circuit breaker frame, MasterPact MTZ2 12H1, 1250A, 66kA/440VAC 50/60Hz (Icu), 3P, fixed, without control unit
Circuit breaker frame, MasterPact MTZ2 12H1, 1250A, 66kA/440VAC 50/60Hz (Icu), 3P, fixed, without control unit
Transformer disconnect, 1500VA, 240x480VAC primary, 120VAC secondary, with outlet, Type 1
Transformer disconnect, 1500VA, 240x480VAC primary, 120VAC secondary, with outlet, Type 1
Transformer, Type T, industrial control, 75VA, 1 phase, 208V primary, 120V secondary, 55C rise
Transformer, Type T, industrial control, 75VA, 1 phase, 208V primary, 120V secondary, 55C rise
Multi 9 – C60H – MCB – 4P – 63 A – D Curve – 415 V – 15 kA
Multi 9 - C60H - MCB - 4P - 63 A - D Curve - 415 V - 15 kA
Multi 9 – C60 UL489 – MCB – 3P – 4 A – D Curve – 480Y/277 V – 10 kA – ring term
Multi 9 - C60 UL489 - MCB - 3P - 4 A - D Curve - 480Y/277 V - 10 kA - ring term
Circuit breaker, PowerPacT H, 110A, 2 pole, 600VAC, 14kA, I-Line, thermal magnetic, 80%, CB
Circuit breaker, PowerPacT H, 110A, 2 pole, 600VAC, 14kA, I-Line, thermal magnetic, 80%, CB
QOU Miniature Circuit Breaker, 20A, 2P, 120/240V, 10kA, Aux Switch
QOU Miniature Circuit Breaker, 20A, 2P, 120/240V, 10kA, Aux Switch
Tap box, I-Line Busway, plug-in, 100A, 3 phase, 4 wire, 600VAC
Tap box, I-Line Busway, plug-in, 100A, 3 phase, 4 wire, 600VAC
Reviews
There are no reviews yet.