Type S non-reversing magnetic starters are for motor control applications. NEMA Size 2 starters have ratings of 10 HP at 200 VAC, 15 HP at 230 VAC and 25 HP at 460 and 575 VAC three phase and has a maximum rating of 45 Amps. This 3 pole starter is for poly phase applications. These starters are available with a wide variety of replaceable coil voltages. Starter has a 110/120 VAC 50/60 Hz operating coil wired for separate control. The Motor Logic solid state overload relay is used to sense over current conditions. A painted sheet steel NEMA 1 general purpose enclosure is used to protect this starter. Enclosure is 12.69 inches tall, 7.81 inches wide and 6.31 inches deep. A wide variety of accessories are available for Type S starters. Type S starters are UL listed and CSA certified for global applications.
Type S nonreversing magnetic starter, NEMA Size 2, 3 P, 110/120 VAC 50/60 Hz coil, Motor Logic overload, NEMA 1
Type S nonreversing magnetic starter, NEMA Size 2, 3 P, 110/120 VAC 50/60 Hz coil, Motor Logic overload, NEMA 1
SKU: 1262959
Category: Starters & Contactors
Reviews (0)
Be the first to review “Type S nonreversing magnetic starter, NEMA Size 2, 3 P, 110/120 VAC 50/60 Hz coil, Motor Logic overload, NEMA 1” Cancel reply
Related products
Contactor, Type S, multipole lighting, mechanically held, 200A, 2 pole, 440/480 VAC 50/60 Hz coil, NEMA 12
Contactor, Type S, multipole lighting, mechanically held, 200A, 2 pole, 440/480 VAC 50/60 Hz coil, NEMA 12
Contactor, Type L, multipole lighting, mechanically held, 30A, 6 pole, 600 V, 110/120 VAC 50/60 Hz coil, NEMA 1, +option
Contactor, Type L, multipole lighting, mechanically held, 30A, 6 pole, 600 V, 110/120 VAC 50/60 Hz coil, NEMA 1, +option
TeSys D contactor – 4P(4 NO) – AC-1 – <= 440 V 80 A – 12 V AC 50 Hz coil
TeSys D contactor - 4P(4 NO) - AC-1 - <= 440 V 80 A - 12 V AC 50 Hz coil
IEC contactor, TeSys Deca, nonreversing, 32A, 20HP at 480VAC, 3 phase, 3 pole, 3 NO, 24VDC coil, open style
IEC contactor, TeSys Deca, nonreversing, 32A, 20HP at 480VAC, 3 phase, 3 pole, 3 NO, 24VDC coil, open style
Contactor, NIGHT MASTER, combination lighting, 30A, 3 pole, breaker, 24 VAC 60 Hz coil. NEMA 3R
Contactor, NIGHT MASTER, combination lighting, 30A, 3 pole, breaker, 24 VAC 60 Hz coil. NEMA 3R
Ambient Compensated Bimetallic Thermal Unit Class 20
Ambient Compensated Bimetallic Thermal Unit Class 20
Contactor, Type S, combination lighting, electrically held, 30A, 3 pole, breaker, 440/480 VAC 50/60 Hz coil, NEMA 1
Contactor, Type S, combination lighting, electrically held, 30A, 3 pole, breaker, 440/480 VAC 50/60 Hz coil, NEMA 1

Reviews
There are no reviews yet.