This XUSL4E Type 4 Safety Light Curtain is designed for finger detection of operator in the vicinity of hazardous machinery. Its transmitter-receiver system creates 45 light beams with a protected height of 460mm. Its PFHD reliability data is 1.52 x 10⁻⁸. It has an aluminum case and its integral LEDs offer a local Signaling for clearly display of device’s status. It can be used as standalone sensor (i.e without safety control unit) or in association with an appropriate safety control unit. It has 2 NO Solid State PNP safety outputs (OSSDs) and meets the requirements of category 4, performance level PL e, SIL 3 as described in EN/ISO 13849-1, EN/IEC 61508 and Type 4 in compliance with EN/IEC 61496-1, EN/IEC 61496-2. Its operating temperature range is -20°C to +55°C and the sensing distance is 0m to 3m or 1m to 6m selectable by wiring.
Safety light curtain type 4, Telemecanique Safety light curtains XUSL, XUSL Finger protection, Std sensing range, Hp = 460 mm, R=14 mm
Safety light curtain type 4, Telemecanique Safety light curtains XUSL, XUSL Finger protection, Std sensing range, Hp = 460 mm, R=14 mm
SKU: 16813299
Category: Sensors & Switches
Reviews (0)
Be the first to review “Safety light curtain type 4, Telemecanique Safety light curtains XUSL, XUSL Finger protection, Std sensing range, Hp = 460 mm, R=14 mm” Cancel reply
Related products
Coded magnetic switch, Telemecanique Safety switches XCS, XCSDMP, 1 NC + 1 NO, staggered, 10 m
Coded magnetic switch, Telemecanique Safety switches XCS, XCSDMP, 1 NC + 1 NO, staggered, 10 m
Photo-electric sensor – XUB – receiver – 90° – Sn 15m – 12..24VDC – M12
Photo-electric sensor - XUB - receiver - 90° - Sn 15m - 12..24VDC - M12
Plastic fibre optic for sensor – diffuse – M3 – 2m – Sn30mm
Plastic fibre optic for sensor - diffuse - M3 - 2m - Sn30mm
Photo-electric sensor – XUM – receiver – 15m – 12..24VDC – cable 2m
Photo-electric sensor - XUM - receiver - 15m - 12..24VDC - cable 2m
Photoelectric sensors XU, XUB, reflex, Sn 4 m, 12…24 VDC, M12
Photoelectric sensors XU, XUB, reflex, Sn 4 m, 12...24 VDC, M12
Pressure switch 9012G – fixed scale – 1 threshold – 13 to 425 psig
Pressure switch 9012G - fixed scale - 1 threshold - 13 to 425 psig
Operating mechanism, disconnect switch, 30 A, 600 VAC, NEMA Size 0 and 1
Operating mechanism, disconnect switch, 30 A, 600 VAC, NEMA Size 0 and 1
pressure switch XMLC 20 bar – adjustable scale 2 thresholds – 2 C/O
pressure switch XMLC 20 bar - adjustable scale 2 thresholds - 2 C/O

Reviews
There are no reviews yet.