Well-Guard pumping plant panels are designed for pumping applications. These panels provide extra space for field installation of auxiliary equipment. These panels use Type S non-reversing magnetic starters. Panel has a LLL36400U31X thermal-magnetic circuit breaker. This panel has a 3 pole NEMA Size 5 non-reversing starter that has a 270 ampere rating. This NEMA Size 5 starter has maximum of 150 HP rating three phase. This non-reversing NEMA motor starter has a Motor Logic overload relay with a 90A to 270A range to sense over current conditions. This NEMA starter has a 100 kA maximum SCCR (Short Circuit Current Rating) per UL508A when protected by an appropriate circuit breaker or fuse. The starters in these panels are available with a wide variety of replaceable coil voltages. The starter in this device has a 110/120 VAC 50/60 Hz operating coil wired for separate control. A painted sheet steel NEMA 3R rainproof enclosure is used to protect this starter. Enclosure is 75.50 inches tall, 22.00 inches wide and 17.55 inches deep. A wide variety of accessories are available for Type S starters. This pump panel is supplied with a START momentary push button and a HAND/OFF/AUTO selector switch. These NEMA pump panels with Type S starters are UL listed and marked Suitable for use as Service Equipment. They are also CSA certified.
Pump Panel, NEMA Type S, Well Guard, Size 5, 270A, 150 HP, LLL36400U31X circuit breaker, Motor Logic SSOLR, 110/120 VAC 50/60 Hz coil, NEMA 3R
Pump Panel, NEMA Type S, Well Guard, Size 5, 270A, 150 HP, LLL36400U31X circuit breaker, Motor Logic SSOLR, 110/120 VAC 50/60 Hz coil, NEMA 3R
SKU: 8970376
Category: Pump Control Panels
Reviews (0)
Be the first to review “Pump Panel, NEMA Type S, Well Guard, Size 5, 270A, 150 HP, LLL36400U31X circuit breaker, Motor Logic SSOLR, 110/120 VAC 50/60 Hz coil, NEMA 3R” Cancel reply
Related products
Pump Panel, NEMA Type S, Well Guard, Size 2, 45A, 5kA SSCR, 30HP, 60A Class H and K fuse clip, Motor Logic SSOLR, 110/120VAC 50/60Hz coil, NEMA 3R
Pump Panel, NEMA Type S, Well Guard, Size 2, 45A, 5kA SSCR, 30HP, 60A Class H and K fuse clip, Motor Logic SSOLR, 110/120VAC 50/60Hz coil, NEMA 3R
Pump Panel, NEMA Type S, Well Guard, oil field, Size 3, 90A, 50HP, 100A fusible disconnect, Motor Logic SSOLR, 110/120VAC 50/60Hz coil, NEMA 3R
Pump Panel, NEMA Type S, Well Guard, oil field, Size 3, 90A, 50HP, 100A fusible disconnect, Motor Logic SSOLR, 110/120VAC 50/60Hz coil, NEMA 3R
Well-Guard Pump Panel Size 3, Motor Logic SSOLR, 480 VAC, NEMA 3R +Options
Well-Guard Pump Panel Size 3, Motor Logic SSOLR, 480 VAC, NEMA 3R +Options
Pump Panel, NEMA Type S, Well Guard, Size 4, 135A, 10 kA SSCR, 100 HP, 200A Class H and K fuse clip, Motor Logic SSOLR, 480 VAC 60 Hz coil, NEMA 3R
Pump Panel, NEMA Type S, Well Guard, Size 4, 135A, 10 kA SSCR, 100 HP, 200A Class H and K fuse clip, Motor Logic SSOLR, 480 VAC 60 Hz coil, NEMA 3R
Pump Panel, NEMA Type S, Well Guard, Size 3, 90A, 5 kA SCCR, 50 HP, 100A Class H and K fuse clip, melting alloy overload, 480 VAC 60 Hz coil, NEMA 3R
Pump Panel, NEMA Type S, Well Guard, Size 3, 90A, 5 kA SCCR, 50 HP, 100A Class H and K fuse clip, melting alloy overload, 480 VAC 60 Hz coil, NEMA 3R
Pump Panel, NEMA Type S, Well Guard, Size 1, 27A, 10HP, 5kA SSCR, 30A fuse clip, Motor Logic SSOLR, 110/120VAC 50/60Hz coil, NEMA 3R
Pump Panel, NEMA Type S, Well Guard, Size 1, 27A, 10HP, 5kA SSCR, 30A fuse clip, Motor Logic SSOLR, 110/120VAC 50/60Hz coil, NEMA 3R
Pump Panel, NEMA Type S, Well Guard, Size 5, 270A, 200HP, LLL36600U31X circuit breaker, Motor Logic SSOLR, 440/480VAC 50/60Hz coil, NEMA 3R
Pump Panel, NEMA Type S, Well Guard, Size 5, 270A, 200HP, LLL36600U31X circuit breaker, Motor Logic SSOLR, 440/480VAC 50/60Hz coil, NEMA 3R
Pump Panel, NEMA Type S, Well Guard, oil field, Size 3, 90A, 50 HP, HLL36100M73 circuit breaker, Motor Logic SSOLR, 480 VAC 60 Hz coil, NEMA 3R
Pump Panel, NEMA Type S, Well Guard, oil field, Size 3, 90A, 50 HP, HLL36100M73 circuit breaker, Motor Logic SSOLR, 480 VAC 60 Hz coil, NEMA 3R
Reviews
There are no reviews yet.