Well-Guard pumping plant panels are designed for pumping applications. These panels provide extra space for field installation of auxiliary equipment. These panels use Type S non-reversing magnetic starters. Panel has a 100A fusible disconnect switch for Class H or K fuses. This panel has a 3 pole NEMA Size 3 non-reversing starter that has a 90 ampere rating. This NEMA Size 3 starter has maximum of 40 HP and 50 HP ratings three phase. This non-reversing NEMA motor starter has a Motor Logic overload relay with a 30A to 90A range to sense over current conditions. This NEMA starter has a 5 kA maximum SCCR (Short Circuit Current Rating) per UL508A when protected by an appropriate circuit breaker or fuse. The starters in these panels are available with a wide variety of replaceable coil voltages. The starter in this device has a 110/120 VAC 50/60 Hz operating coil wired for separate control. A painted sheet steel NEMA 3R rainproof enclosure is used to protect this starter. Enclosure is 49.00 inches tall, 19.15 inches wide and 10.37 inches deep. A wide variety of accessories are available for Type S starters. Panel has a door wind latch. This pump panel is also supplied with a START momentary push button and a HAND/OFF/AUTO selector switch. These NEMA pump panels with Type S starters are UL listed and marked Suitable for use as Service Equipment. They are also CSA certified.
Pump Panel, NEMA Type S, Well Guard, Size 3, 90A, 5 kA SCCR, 50 HP, 100A Class H and K fuse clip, Motor Logic SSOLR, 120 VAC 60 Hz coil, NEMA 3R
Pump Panel, NEMA Type S, Well Guard, Size 3, 90A, 5 kA SCCR, 50 HP, 100A Class H and K fuse clip, Motor Logic SSOLR, 120 VAC 60 Hz coil, NEMA 3R
SKU: 8993121
Category: Automation & Control
Reviews (0)
Be the first to review “Pump Panel, NEMA Type S, Well Guard, Size 3, 90A, 5 kA SCCR, 50 HP, 100A Class H and K fuse clip, Motor Logic SSOLR, 120 VAC 60 Hz coil, NEMA 3R” Cancel reply
Related products
Limit switch, Limit switches XC Standard, XCMN, steel roller plunger, 1NC+1 NO, snap, cable
Limit switch, Limit switches XC Standard, XCMN, steel roller plunger, 1NC+1 NO, snap, cable
Contactor, Definite Purpose, 30A, 2 pole, 110/120VAC 50/60Hz coil, open
Contactor, Definite Purpose, 30A, 2 pole, 110/120VAC 50/60Hz coil, open
TeSys K reversing contactor – 3P – AC-3 <= 440 V 9 A – 1 NC – 24 V AC coil
TeSys K reversing contactor - 3P - AC-3 <= 440 V 9 A - 1 NC - 24 V AC coil
Inductive proximity sensors XS for hazardous area dust, M12, Sn4mm, 12…48 VDC, NC, cable 10 m
Inductive proximity sensors XS for hazardous area dust, M12, Sn4mm, 12...48 VDC, NC, cable 10 m
discrete output module Modicon Quantum – 32 O – positive logic (source)
discrete output module Modicon Quantum - 32 O - positive logic (source)
Reviews
There are no reviews yet.