Well-Guard pumping plant panels are designed for pumping applications. These panels provide extra space for field installation of auxiliary equipment. These panels use Type S non-reversing magnetic starters. Panel has a 100A fusible disconnect switch for Class H or K fuses. This panel has a 3 pole NEMA Size 3 non-reversing starter that has a 90 ampere rating. This NEMA Size 3 starter has maximum of 20 HP, 25 HP and 30 HP ratings three phase. This non-reversing NEMA motor starter has a Motor Logic overload relay with a 30A to 90A range to sense over current conditions. This NEMA starter has a 5 kA maximum SCCR (Short Circuit Current Rating) per UL508A when protected by an appropriate circuit breaker or fuse. The starters in these panels are available with a wide variety of replaceable coil voltages. The starter in this device has a 220/240 VAC 50/60 Hz operating coil wired for common control. A painted sheet steel NEMA 3R rainproof enclosure is used to protect this starter. Enclosure is 49.00 inches tall, 19.15 inches wide and 10.37 inches deep. A wide variety of accessories are available for Type S starters. This pump panel is supplied with a START momentary push button and a HAND/OFF/AUTO selector switch. These NEMA pump panels with Type S starters are UL listed and marked Suitable for use as Service Equipment. They are also CSA certified.
Pump Panel, NEMA Type S, Well Guard, Size 3, 90A, 5 kA SSCR, 30 HP, 100A Class H and K fuse clip, Motor Logic SSOLR, 240 VAC 60 Hz coil, NEMA 3R
Pump Panel, NEMA Type S, Well Guard, Size 3, 90A, 5 kA SSCR, 30 HP, 100A Class H and K fuse clip, Motor Logic SSOLR, 240 VAC 60 Hz coil, NEMA 3R
SKU: 14506760
Category: Pump Control Panels
Reviews (0)
Be the first to review “Pump Panel, NEMA Type S, Well Guard, Size 3, 90A, 5 kA SSCR, 30 HP, 100A Class H and K fuse clip, Motor Logic SSOLR, 240 VAC 60 Hz coil, NEMA 3R” Cancel reply
Related products
Pump Panel, NEMA Type S, Well Guard, Size 5, 270A, 200HP, LLL36600U31X circuit breaker, Motor Logic SSOLR, 440/480VAC 50/60Hz coil, NEMA 3R
Pump Panel, NEMA Type S, Well Guard, Size 5, 270A, 200HP, LLL36600U31X circuit breaker, Motor Logic SSOLR, 440/480VAC 50/60Hz coil, NEMA 3R
Pump Panel, NEMA Type S, Well Guard, Size 1, 27A, 10HP, 5kA SSCR, 30A fuse clip, Motor Logic SSOLR, 110/120VAC 50/60Hz coil, NEMA 3R
Pump Panel, NEMA Type S, Well Guard, Size 1, 27A, 10HP, 5kA SSCR, 30A fuse clip, Motor Logic SSOLR, 110/120VAC 50/60Hz coil, NEMA 3R
Pump Panel, NEMA Type S, Well Guard, Size 1, 27A, 3 HP, 5 kA SSCR, 30A fuse clip, IEC bimetallic overload, 440/480 VAC 50/60 Hz coil, NEMA 3R
Pump Panel, NEMA Type S, Well Guard, Size 1, 27A, 3 HP, 5 kA SSCR, 30A fuse clip, IEC bimetallic overload, 440/480 VAC 50/60 Hz coil, NEMA 3R
Pump Panel, NEMA Type S, Well Guard, oil field, Size 4, 135A, 100 HP, JLL36250M75 circuit breaker, Motor Logic SSOLR, 480 VAC 60 Hz coil, NEMA 3R
Pump Panel, NEMA Type S, Well Guard, oil field, Size 4, 135A, 100 HP, JLL36250M75 circuit breaker, Motor Logic SSOLR, 480 VAC 60 Hz coil, NEMA 3R
Pump Panel, NEMA Type S, Well Guard, Size 3, 90A, 50 HP, HLL36100M73 MCP, melting alloy overload, 110/120 VAC 50/60 Hz coil, NEMA 3R
Pump Panel, NEMA Type S, Well Guard, Size 3, 90A, 50 HP, HLL36100M73 MCP, melting alloy overload, 110/120 VAC 50/60 Hz coil, NEMA 3R
Well-Guard Pump Panel Size 4, Motor Logic SSOLR, 480 VAC, NEMA 3R +Options
Well-Guard Pump Panel Size 4, Motor Logic SSOLR, 480 VAC, NEMA 3R +Options
Pump Panel, NEMA Type S, Well Guard, oil field, Size 4, 135A, 100HP, 200A fusible disconnect, Motor Logic SSOLR, 440/480VAC 50/60Hz coil, NEMA 3R
Pump Panel, NEMA Type S, Well Guard, oil field, Size 4, 135A, 100HP, 200A fusible disconnect, Motor Logic SSOLR, 440/480VAC 50/60Hz coil, NEMA 3R
Pump Panel, NEMA Type S, Well Guard, oil field, Size 2, 45A, 25HP, HLL36050M72 circuit breaker, Motor Logic SSOLR, 120VAC 60Hz coil, NEMA 3R
Pump Panel, NEMA Type S, Well Guard, oil field, Size 2, 45A, 25HP, HLL36050M72 circuit breaker, Motor Logic SSOLR, 120VAC 60Hz coil, NEMA 3R
Reviews
There are no reviews yet.