Well-Guard pumping plant panels are designed for pumping applications. These panels provide extra space for field installation of auxiliary equipment. These panels use Type S non-reversing magnetic starters. Panel has a 60A fusible disconnect switch for Class H or K fuses. This panel has a 3 pole NEMA Size 2 non-reversing starter that has a 45 ampere rating. This NEMA Size 2 starter has maximum of 10 HP and 15 HP ratings three phase. This non-reversing NEMA motor starter has a Motor Logic overload relay with a 15A to 45A range to sense over current conditions. This NEMA starter has a 5 kA maximum SCCR (Short Circuit Current Rating) per UL508A when protected by an appropriate circuit breaker or fuse. The starters in these panels are available with a wide variety of replaceable coil voltages. The starter in this device has a 110/120 VAC 50/60 Hz operating coil wired for separate control. A painted sheet steel NEMA 3R rainproof enclosure is used to protect this starter. Enclosure is 39.05 inches tall, 13.73 inches wide and 9.70 inches deep. A wide variety of accessories are available for Type S starters. This pump panel is supplied with a START momentary push button and a HAND/OFF/AUTO selector switch. These NEMA pump panels with Type S starters are UL listed and marked Suitable for use as Service Equipment. They are also CSA certified.
Pump Panel, NEMA Type S, Well Guard, Size 2, 45A, 5 kA SSCR, 15 HP, 60A Class H and K fuse clip, Motor Logic SSOLR, 110/120 VAC 50/60 Hz coil, NEMA 3R
Pump Panel, NEMA Type S, Well Guard, Size 2, 45A, 5 kA SSCR, 15 HP, 60A Class H and K fuse clip, Motor Logic SSOLR, 110/120 VAC 50/60 Hz coil, NEMA 3R
SKU: 14530583
Category: Pump Control Panels
Reviews (0)
Be the first to review “Pump Panel, NEMA Type S, Well Guard, Size 2, 45A, 5 kA SSCR, 15 HP, 60A Class H and K fuse clip, Motor Logic SSOLR, 110/120 VAC 50/60 Hz coil, NEMA 3R” Cancel reply
Related products
Pump Panel, NEMA Type S, Well Guard, oil field, Size 1, 27A, 10 HP, 30A fusible disconnect, Motor Logic SSOLR, 440/480 VAC 50/60 Hz coil, NEMA 3R
Pump Panel, NEMA Type S, Well Guard, oil field, Size 1, 27A, 10 HP, 30A fusible disconnect, Motor Logic SSOLR, 440/480 VAC 50/60 Hz coil, NEMA 3R
Pump Panel, NEMA Type S, Well Guard, Size 3, 90A, 5 kA SCCR, 50 HP, 100A Class H and K fuse clip, Motor Logic SSOLR, 480 VAC 60 Hz coil, NEMA 3R
Pump Panel, NEMA Type S, Well Guard, Size 3, 90A, 5 kA SCCR, 50 HP, 100A Class H and K fuse clip, Motor Logic SSOLR, 480 VAC 60 Hz coil, NEMA 3R
Pump Panel, NEMA Type S, Well Guard, Size 2, 45A, 5kA SSCR, 30HP, 60A Class H and K fuse clip, Motor Logic SSOLR, 110/120VAC 50/60Hz coil, NEMA 3R
Pump Panel, NEMA Type S, Well Guard, Size 2, 45A, 5kA SSCR, 30HP, 60A Class H and K fuse clip, Motor Logic SSOLR, 110/120VAC 50/60Hz coil, NEMA 3R
Pump Panel, NEMA Type S, Well Guard, Size 5, 270A, 200HP, LLL36600U31X circuit breaker, Motor Logic SSOLR, 440/480VAC 50/60Hz coil, NEMA 3R
Pump Panel, NEMA Type S, Well Guard, Size 5, 270A, 200HP, LLL36600U31X circuit breaker, Motor Logic SSOLR, 440/480VAC 50/60Hz coil, NEMA 3R
Pump Panel, NEMA Type S, Well Guard, Size 1, 27A, 3 HP, 5 kA SSCR, 30A fuse clip, IEC bimetallic overload, 440/480 VAC 50/60 Hz coil, NEMA 3R
Pump Panel, NEMA Type S, Well Guard, Size 1, 27A, 3 HP, 5 kA SSCR, 30A fuse clip, IEC bimetallic overload, 440/480 VAC 50/60 Hz coil, NEMA 3R
Pump Panel, NEMA Type S, Well Guard, Size 1, 27A, 5 kA SSCR, 7.5 HP, 30A fuse clip, Motor Logic SSOLR, 110/120 VAC 50/60 Hz coil, NEMA 3R
Pump Panel, NEMA Type S, Well Guard, Size 1, 27A, 5 kA SSCR, 7.5 HP, 30A fuse clip, Motor Logic SSOLR, 110/120 VAC 50/60 Hz coil, NEMA 3R
Pump Panel, NEMA Type S, Well Guard, Size 2, 45A, 5 kA SSCR, 25 HP, 60A Class H and K fuse clip, Motor Logic SSOLR, 110/120 VAC 50/60 Hz coil, NEMA 3R
Pump Panel, NEMA Type S, Well Guard, Size 2, 45A, 5 kA SSCR, 25 HP, 60A Class H and K fuse clip, Motor Logic SSOLR, 110/120 VAC 50/60 Hz coil, NEMA 3R
Pump Panel, NEMA Type S, Well Guard, Size 1, 27A, 10HP, 5kA SSCR, 30A fuse clip, Motor Logic SSOLR, 110/120VAC 50/60Hz coil, NEMA 3R
Pump Panel, NEMA Type S, Well Guard, Size 1, 27A, 10HP, 5kA SSCR, 30A fuse clip, Motor Logic SSOLR, 110/120VAC 50/60Hz coil, NEMA 3R
Reviews
There are no reviews yet.