The purpose of ground-fault protection is to measure the ground leakage current of an electrical installation, or part of an installation, and interrupt the power supply if the ground-fault current becomes dangerous to property. Vigirex™ ground-fault relays, with associated sensors (current transformers), measure the leakage current in an electrical installation to detect levels that may be damaging. When used for protection, they cause an associated circuit breaker or switch to interrupt the supply of power to the protected system. They may also be used for monitoring only, with output to an alarm. The Vigirex product line can be used with loads up to 3200A. It includes fixed sensitivities from 30 mA to 1 A and adjustable sensitivities up to 30 A, providing a solution that offers both flexibility and performance. The responsiveness of the Vigirex relay is determined from a combination of their sensitivity (measured in milliamperes or amps) and their time delays (duration that the threshold of ground-fault is exceeded). These can range from instantaneous (no intentional delay) to 4.5 seconds. The shortest delay will provide the greatest protection, while the longest will minimize nuisance tripping. The range of time delays is also helpful when providing a coordinated ground-fault protection scheme. This Vigirex, time delay switch is rail mounted. This product complys to UL standards. This product has a control current voltage of 110-130 VAC.
GFR RH99M MANUAL TIME DELAY UL 120VAC
GFR RH99M MANUAL TIME DELAY UL 120VAC
SKU: 1435207
Category: Circuit Breakers
Reviews (0)
Be the first to review “GFR RH99M MANUAL TIME DELAY UL 120VAC” Cancel reply
Related products
Circuit breaker frame, MasterPact MTZ2 32H2, 3200A, 100kA/440VAC 50/60Hz (Icu), 4P, drawout, without control unit
Circuit breaker frame, MasterPact MTZ2 32H2, 3200A, 100kA/440VAC 50/60Hz (Icu), 4P, drawout, without control unit
Circuit breaker, ComPact NSX250H, 70kA/415VAC, TMD trip unit 160A, 3 poles 3d
Circuit breaker, ComPact NSX250H, 70kA/415VAC, TMD trip unit 160A, 3 poles 3d
Miniature circuit breaker (MCB), Multi9 C60BP, 3P, 3A, C curve, 10kA (UL489), 10kA (IEC/EN 60947-2)
Miniature circuit breaker (MCB), Multi9 C60BP, 3P, 3A, C curve, 10kA (UL489), 10kA (IEC/EN 60947-2)
Circuit breaker, PowerPacT B, 15A, 3 pole, 600Y/347VAC, 14kA, I-Line, thermal magnetic, 80%, ABC
Circuit breaker, PowerPacT B, 15A, 3 pole, 600Y/347VAC, 14kA, I-Line, thermal magnetic, 80%, ABC
Circuit breaker, PowerPacT M, 600A, 3 pole, 600VAC, 18kA, lugs, ET 1.0, 80%
Circuit breaker, PowerPacT M, 600A, 3 pole, 600VAC, 18kA, lugs, ET 1.0, 80%
Circuit breaker, PowerPacT H, thermal magnetic, unit mount, 60A, 3 pole, 18 kA, 600 VAC, shunt trip, copper lugs, 80%
Circuit breaker, PowerPacT H, thermal magnetic, unit mount, 60A, 3 pole, 18 kA, 600 VAC, shunt trip, copper lugs, 80%
Circuit breaker, PowerPact L, unit mount, Micrologic 3.3S, 600A, 3 pole, 35kA, 480VAC, 80% rated, mission critical
Circuit breaker, PowerPact L, unit mount, Micrologic 3.3S, 600A, 3 pole, 35kA, 480VAC, 80% rated, mission critical
Mini circuit breaker, QO, 20A, 3 pole, 240VAC, 10kA, 100mA grd fault B, bolt on mount, ring
Mini circuit breaker, QO, 20A, 3 pole, 240VAC, 10kA, 100mA grd fault B, bolt on mount, ring