Thermal units are intended to protect motors, controllers, and branch circuit conductors against excessive heating due to prolonged motor over currents up to and including locked rotor currents. Protection of the motor and the other branch circuit components from higher currents, due to short circuits or grounds, is a function of the branch circuit fuses or circuit breakers. Class 20 thermal units respond to overload current conditions according to trip curves. These thermal units will trip in 20 seconds or less on overload conditions. These thermal units will trip in 20 seconds or less on overload conditions. These thermal units have a one piece construction. The motor current passes through a small heater winding within these thermal units. Under overload conditions, the heat causes a special solder to melt allowing a ratchet wheel to spin free thus opening the control circuit contacts and opening the motor contacts.
Thermal Unit, Type S, Type A, melting alloy, Class 20
Thermal Unit, Type S, Type A, melting alloy, Class 20
SKU: 1266370
Category: NEMA Contactors & Starters
Reviews (0)
Be the first to review “Thermal Unit, Type S, Type A, melting alloy, Class 20” Cancel reply
Related products
TeSys F contactor – 3P (3 NO) – AC-3 – <= 440 V 115 A – coil 120 V AC
TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 115 A - coil 120 V AC
NEMA Combination Starter, Type S, HHL electronic motor circuit protector, Size 4, 135A, 100HP at 600VAC 3 phase, melting alloy, 120VAC coil, NEMA 12
NEMA Combination Starter, Type S, HHL electronic motor circuit protector, Size 4, 135A, 100HP at 600VAC 3 phase, melting alloy, 120VAC coil, NEMA 12
NEMA Contactor, Type S, nonreversing, Size 3, 90A, 50HP at 575VAC, 3 phase, up to 100kA, 3 pole, 120VAC coil, NEMA 1
NEMA Contactor, Type S, nonreversing, Size 3, 90A, 50HP at 575VAC, 3 phase, up to 100kA, 3 pole, 120VAC coil, NEMA 1
IEC contactor, TeSys Deca, nonreversing, 18A, 10HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, low consumption 12VDC coil
IEC contactor, TeSys Deca, nonreversing, 18A, 10HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, low consumption 12VDC coil
IEC contactor, TeSys Deca, nonreversing, 60A resistive, 4 pole, 2 NO and 2 NC, 230VAC 50/60Hz coil, open style
IEC contactor, TeSys Deca, nonreversing, 60A resistive, 4 pole, 2 NO and 2 NC, 230VAC 50/60Hz coil, open style
TeSys Deca reversing contactor – 3P(3 NO) – AC-3 – <= 440 V 18 A – 48 V AC coil
TeSys Deca reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 18 A - 48 V AC coil
NEMA Motor Starter, Type S, nonreversing, Size 0, 18A, 5 HP at 460 VAC, up to 100 kA SCCR, 3 phase, 3 pole, Motor Logic, 120 VAC coil, open
NEMA Motor Starter, Type S, nonreversing, Size 0, 18A, 5 HP at 460 VAC, up to 100 kA SCCR, 3 phase, 3 pole, Motor Logic, 120 VAC coil, open
IEC contactor, TeSys Deca, nonreversing, 9A, 5HP at 480VAC, 3 phase, 3 pole, 3 NO, 110VAC 50/60Hz coil, open style
IEC contactor, TeSys Deca, nonreversing, 9A, 5HP at 480VAC, 3 phase, 3 pole, 3 NO, 110VAC 50/60Hz coil, open style
Reviews