Facebook Twitter Pinterest linkedin Telegram
Cuny & Guerber Cuny & Guerber
  • Home
  • About Us
    • History
    • Capabilities
  • Product Lines
    • Automation
    • Circuit Protection
    • Distribution
    • Electrical Enclosures
    • Machine Control
    • Motor Control
    • Contractor Supplies
  • Schneider Catalog
  • Contact Us
    • Careers
Menu
Cuny & Guerber
primary_image
Click to enlarge
HomeAutomation & Control Disconnect switch, TeSys VLS, body switch, 40A, 20HP at 480VAC, UL508, three phase, 5kA SCCR, size 1, door mount
Previous product
primary_image
AC servo motor BSH, Lexium 15, 0.5N.m, 4000rpm, keyed shaft, without brake, IP65
Back to products
Next product
primary_image
Safety switch, double throw, non fusible, 60A, 600V, 3 pole, 60HP, NEMA 12, no knock outs

Disconnect switch, TeSys VLS, body switch, 40A, 20HP at 480VAC, UL508, three phase, 5kA SCCR, size 1, door mount

Disconnect switch, TeSys VLS, body switch, 40A, 20HP at 480VAC, UL508, three phase, 5kA SCCR, size 1, door mount

SKU: 4664372 Category: Automation & Control
Share
Facebook Twitter Pinterest linkedin Telegram
  • Description
  • Reviews (0)
Description

These TeSys VLS disconnect switches are for integration into control systems in applications like material handling, HVAC, pumping, solar energy, mining and many more. This family of disconnect switches has switches ranging from 16A to 125A. The 16A, 25A, 32A, 40A and 63A disconnect switches are UL508 motor disconnect switches rated. The 30A, 63A, 80A, 100A and 125A disconnect switches are UL98 non fusible disconnect switch rated. This 40A disconnect switch has 3 normally open poles and mounts directly in the enclosure door. Per UL and CSA this this disconnect switch has a 2 HP rating at 120 VAC and a 5 HP at 240 VAC single phase. Per UL and CSA this disconnect switch has a 10 HP rating at 200 to 208 VAC, a 15 HP rating at 240 VAC, a 20 HP rating at 480 VAC and a 25 HP rating at 600 VAC three phase. Per UL508A this this disconnect switch has up to a 5 kA at 600 V short circuit current rating (SCCR) with a 30A Type RK5 fuse maximum. Per IEC requirements, this disconnect switch has a 18.5 kW rating at 400 V, a 18.5 kW rating at 500 V and a 22 kW rating at 690V three phase. The screw clamp terminals will accept 10 mm solid or 16 mm stranded wire. The clamps will also accept solid or stranded wire from 18 AWG to 6 AWG. This disconnect switch is 3.07 inches tall, 1.77 inches wide and 2.87 inches deep. The switch weighs 0.30 lbs. There are many handles and accessories available this TeSys VLS disconnect switch. This TeSys VLS disconnect switch is UL Listed per UL60947-4-1, CSA certified per CSA 22.2 and meets IEC 60947-3 requirements.

Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Disconnect switch, TeSys VLS, body switch, 40A, 20HP at 480VAC, UL508, three phase, 5kA SCCR, size 1, door mount” Cancel reply

Your email address will not be published. Required fields are marked *

Related products

primary_image
Close

TeSys Deca thermal overload relays – 23…32 A – class 10A

TeSys Deca thermal overload relays - 23...32 A - class 10A
Quick view
primary_image
Close

Inductive proximity sensors XS for hazardous area dust, M12, Sn4mm, 12…48 VDC, NC, cable 10 m

Inductive proximity sensors XS for hazardous area dust, M12, Sn4mm, 12...48 VDC, NC, cable 10 m
Quick view
primary_image
Close

Harmony XB4, Light block with body/fixing collar, metal, blue, integral LED, 24 V AC/DC, 2 NO

Harmony XB4, Light block with body/fixing collar, metal, blue, integral LED, 24 V AC/DC, 2 NO
Quick view
primary_image
Close

Set of 2 heavy duty vertical rails for fixing of chassis and cross rails-2000 mm

Set of 2 heavy duty vertical rails for fixing of chassis and cross rails-2000 mm
Quick view
primary_image
Close

Mechanical alternator, Square D Pumptrol, closed tank, NEMA 1, screw in bushing, 4NC DPST DB contacts

Mechanical alternator, Square D Pumptrol, closed tank, NEMA 1, screw in bushing, 4NC DPST DB contacts
Quick view
Placeholder
Close

Melting Alloy Thermal Unit Class 30

Melting Alloy Thermal Unit Class 30
Quick view
primary_image
Close

Contactor, Definite Purpose, 40A, 2 pole, 7.5 HP at 230 VAC, 1 phase, 440/480 VAC 50/60 Hz coil, open

Contactor, Definite Purpose, 40A, 2 pole, 7.5 HP at 230 VAC, 1 phase, 440/480 VAC 50/60 Hz coil, open
Quick view
primary_image
Close

Harmony XB5, Antimicrobial Flush mounted push button head, plastic, projecting, black, Ø30, spring return, unmarked, dark grey bezel

Harmony XB5, Antimicrobial Flush mounted push button head, plastic, projecting, black, Ø30, spring return, unmarked, dark grey bezel
Quick view
  • LOCATION

    305 Clearview Rd, Suite 2
    Edison, NJ 08837

  • PHONE

    (201)617-5800 |

    FAX

    (201)617-5557

  • EMAIL

    sales@cuny.biz

Contact

201-617-5800

Hours of Operations: Counter Hours: 6:30am - 5pm Office Hours: 8am - 5pm Monday - Friday
Product Line
  • Contractor Supplies
  • Machine Control
  • Electrical Enclosures
  • Distribution
  • Circuit Protection
  • Automation
Contact Us Copyright 2020 Cuny & Guerber, Inc All Rights Reserved
  • Home
  • About Us
    • History
    • Capabilities
  • Product Lines
    • Automation
    • Circuit Protection
    • Distribution
    • Electrical Enclosures
    • Machine Control
    • Motor Control
    • Contractor Supplies
  • Schneider Catalog
  • Contact Us
    • Careers
Scroll To Top