TeSys N contactors and starters conform to NEMA ICS2 standards. The NEMA size is printed directly on the face of the contactor. The 3 pole NEMA size 0 motor starter has an 18 amperage continuous current rating. It also has ratings of 3 HP at 200 to 230 Vac and 5 HP at 460 and 575 VAC poly phase. This motor starter has a Motor Logic solid state overload relay with a Class 10/20 rating. The overload is adjustable from 6 to 18 amperes. The starter has a 120 VAC replaceable coil with common control. Starter has 1 normally open and 1 normally closed auxiliary contact. This starter is not in an enclosure. Motor starter is UL listed and CSA Certified.
Motor Starter, TeSys NEMA, nonreversing, Size 0, 18A, 3 pole, HP rated, Motor Logic SSOLR, 120 VAC 60 Hz coil, open
Motor Starter, TeSys NEMA, nonreversing, Size 0, 18A, 3 pole, HP rated, Motor Logic SSOLR, 120 VAC 60 Hz coil, open
SKU: 516010
Category: NEMA Contactors & Starters
Reviews (0)
Be the first to review “Motor Starter, TeSys NEMA, nonreversing, Size 0, 18A, 3 pole, HP rated, Motor Logic SSOLR, 120 VAC 60 Hz coil, open” Cancel reply
Related products
NEMA Combination Starter, Type S, nonfusible disconnect, Size 1, 27A, 10HP at 600VAC, 3 phase, 3 pole, melting alloy, 120VAC coil, NEMA 12
NEMA Combination Starter, Type S, nonfusible disconnect, Size 1, 27A, 10HP at 600VAC, 3 phase, 3 pole, melting alloy, 120VAC coil, NEMA 12
NEMA Motor Starter, Type S, nonreversing, Size 2, 45A, 7.5 HP at 230 VAC, 5 kA SCCR, 1 phase, 2 pole, melting alloy, 240 VAC coil, NEMA 1
NEMA Motor Starter, Type S, nonreversing, Size 2, 45A, 7.5 HP at 230 VAC, 5 kA SCCR, 1 phase, 2 pole, melting alloy, 240 VAC coil, NEMA 1
IEC contactor, TeSys Deca, nonreversing, 20A resistive, 4 pole, 2 NO and 2 NC, 24VDC coil, open style
IEC contactor, TeSys Deca, nonreversing, 20A resistive, 4 pole, 2 NO and 2 NC, 24VDC coil, open style
Thermal Unit, Type S, Type CC, melting alloy, Class 20
Thermal Unit, Type S, Type CC, melting alloy, Class 20
IEC contactor, TeSys Deca, nonreversing, 12A, 7.5HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 220VAC 50/60Hz coil, open
IEC contactor, TeSys Deca, nonreversing, 12A, 7.5HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 220VAC 50/60Hz coil, open
IEC contactor, TeSys Deca, nonreversing, 60A resistive, 4 pole, 2 NO and 2 NC, 230VAC 50/60Hz coil, open style
IEC contactor, TeSys Deca, nonreversing, 60A resistive, 4 pole, 2 NO and 2 NC, 230VAC 50/60Hz coil, open style
NEMA Contactor, Type S, nonreversing, Size 3, 90A, 50HP at 575VAC, 3 phase, up to 100kA, 3 pole, 120VAC coil, NEMA 1
NEMA Contactor, Type S, nonreversing, Size 3, 90A, 50HP at 575VAC, 3 phase, up to 100kA, 3 pole, 120VAC coil, NEMA 1
NEMA Motor Starter, Type S, nonreversing, Size 0, 18A, 5 HP at 460 VAC, up to 100 kA SCCR, 3 phase, 3 pole, Motor Logic, 120 VAC coil, open
NEMA Motor Starter, Type S, nonreversing, Size 0, 18A, 5 HP at 460 VAC, up to 100 kA SCCR, 3 phase, 3 pole, Motor Logic, 120 VAC coil, open

Reviews
There are no reviews yet.