TeSys N contactors and starters conform to NEMA ICS2 standards. The NEMA size is printed directly on the face of the contactor. This 3 pole NEMA size 2 nonreversing contactor mounts on 35mm DIN rail and has a 45 amperage continuous current rating. This contactor has 3 HP at 115 VAC and 7.5 HP at 230 VAC single phase ratings. To maximize convenience and to reduce inventory the TeSys N contactor uses the common TeSys accessories. The nonreversing contactor is wired for common control with a 120 VAC 50/60 Hz replaceable coil. Contactor has 1 normally open and 1 normally closed auxiliary contact. This contactor is not in an enclosure. This contactor is 5.47 inches tall, 2.16 inches wide and 4.72 inches deep. It weighs 2.08 lbs. The screw clamp terminals will accept power wires from 16 AWG to 4 AWG and control wires from 16 AWG to 12 AWG. This TeSys N contactor is UL listed and CSA Certified.
Contactor, Tesys N Contactors, nonreversing, 3P, 3phase, 45A, 25HP at 460VAC, NEMA size 2, 120VAC 50/60Hz coil, open
Contactor, Tesys N Contactors, nonreversing, 3P, 3phase, 45A, 25HP at 460VAC, NEMA size 2, 120VAC 50/60Hz coil, open
SKU: 483949
Category: Starters & Contactors
Reviews (0)
Be the first to review “Contactor, Tesys N Contactors, nonreversing, 3P, 3phase, 45A, 25HP at 460VAC, NEMA size 2, 120VAC 50/60Hz coil, open” Cancel reply
Related products
IEC contactor, TeSys Deca, nonreversing, 32A, 20HP at 480VAC, 3 phase, 3 pole, 3 NO, 24VDC coil, open style
IEC contactor, TeSys Deca, nonreversing, 32A, 20HP at 480VAC, 3 phase, 3 pole, 3 NO, 24VDC coil, open style
Panelboard lighting contactor auxiliary contact module, top assembly, 1NO-1NC
Panelboard lighting contactor auxiliary contact module, top assembly, 1NO-1NC
Reversing ultra compact starter, TeSys Hybrid, 3P, 500VAC, 0.75kW at 400V, 110 to 230VAC, Spring terminal
Reversing ultra compact starter, TeSys Hybrid, 3P, 500VAC, 0.75kW at 400V, 110 to 230VAC, Spring terminal
Contactor TeSys LC1-K – 3 poles – AC-3 440V 9 A – coil 24 V AC
Contactor TeSys LC1-K - 3 poles - AC-3 440V 9 A - coil 24 V AC
NEMA Contactor, Type S, nonreversing, Size 1, 27A, 10 HP at 575 VAC, 3 phase, up to 100 kA, 3 pole, 120 VAC coil, open
NEMA Contactor, Type S, nonreversing, Size 1, 27A, 10 HP at 575 VAC, 3 phase, up to 100 kA, 3 pole, 120 VAC coil, open
Contactor, Type L, multipole lighting, mechanically held, 30A, 10 pole, 600 V, 110/120 VAC 50/60 Hz coil, open style
Contactor, Type L, multipole lighting, mechanically held, 30A, 10 pole, 600 V, 110/120 VAC 50/60 Hz coil, open style
TeSys D contactor – 4P(4 NO) – AC-1 – <= 440 V 60 A – 12 V DC standard coil
TeSys D contactor - 4P(4 NO) - AC-1 - <= 440 V 60 A - 12 V DC standard coil
Contactor, Type L, multipole lighting, mechanically held, 30A, 6 pole, 600 V, 110/120 VAC 50/60 Hz coil, NEMA 1, +option
Contactor, Type L, multipole lighting, mechanically held, 30A, 6 pole, 600 V, 110/120 VAC 50/60 Hz coil, NEMA 1, +option

Reviews
There are no reviews yet.