Facebook Twitter Pinterest linkedin Telegram
Cuny & Guerber Cuny & Guerber
  • Home
  • About Us
    • History
    • Capabilities
  • Product Lines
    • Automation
    • Circuit Protection
    • Distribution
    • Electrical Enclosures
    • Machine Control
    • Motor Control
    • Contractor Supplies
  • Schneider Catalog
  • Contact Us
    • Careers
Menu
Cuny & Guerber
primary_image
Click to enlarge
HomeAutomation & Control TeSys Deca thermal overload relays – 30…40 A – class 20
Previous product
primary_image
IEC contactor, TeSys Deca, nonreversing, 12A, 7.5HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 110VDC coil, open style
Back to products
Next product
primary_image
Panelboard interior, NF, main lugs, 400A, Cu bus, Al neutral assembly, 30 pole spaces, 3 phase, 4 wire, 600Y/347VAC max

TeSys Deca thermal overload relays – 30…40 A – class 20

TeSys Deca thermal overload relays – 30…40 A – class 20

SKU: 508582 Category: Automation & Control
Share
Facebook Twitter Pinterest linkedin Telegram
  • Description
  • Reviews (0)
Description

LRD340L is a TeSys LRD thermal overload relay from Schneider Electric to be used with a TeSys D contactor. It protects motors 18.5kW@400V thanks to a thermal range 30-40A, a tripping class 20 and phase unbalance protection. LRD340L is a TeSys LRD thermal overload relay from Schneider Electric for direct mounting on TeSys D contactors. With a thermal setting range 30-40A, a tripping class 20 and phase unbalance detection, it protects motors 18.5kW@400V. It provides manual test & reset buttons, automatic reset, trip auxiliary contact and flag indicator. Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine) and Green Premium compliant (RoHs/Reach). Thermal overload protection relay, bimetallic type, with phase unbalance protection (differential). Direct mounting on the bottom terminals of a Tesys contactor LC1D40A-D65A to form a compact starter. Light and compact, 55mm wide. Temperature compensated for a good accuracy of the protection. Manual control with test & reset buttons, manual / automatic reset selector. Trip signaling with 1NO+1NC auxiliary contacts and trip flag indicator. Can be completed with terminal blocks for separate mounting (LAD7B, LAD96) and remote control devices (LAD703, LA7D03).

Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “TeSys Deca thermal overload relays – 30…40 A – class 20” Cancel reply

Your email address will not be published. Required fields are marked *

Related products

primary_image
Close

10.4-inch installation gasket Magelis HMIGTO

10.4-inch installation gasket Magelis HMIGTO
Quick view
primary_image
Close

Set of 2 heavy duty vertical rails for fixing of chassis and cross rails-2000 mm

Set of 2 heavy duty vertical rails for fixing of chassis and cross rails-2000 mm
Quick view
primary_image
Close

Contactor, Definite Purpose, 40A, 2 pole, 7.5 HP at 230 VAC, 1 phase, 440/480 VAC 50/60 Hz coil, open

Contactor, Definite Purpose, 40A, 2 pole, 7.5 HP at 230 VAC, 1 phase, 440/480 VAC 50/60 Hz coil, open
Quick view
Placeholder
Close

TeSys K reversing contactor – 3P – AC-3 <= 440 V 9 A – 1 NC – 24 V AC coil

TeSys K reversing contactor - 3P - AC-3 <= 440 V 9 A - 1 NC - 24 V AC coil
Quick view
primary_image
Close

Safety light curtain type 4, Telemecanique Safety light curtains XUSL, XUSL Body protection, Std sensing range, 3 Beams, Hp = 810 mm

Safety light curtain type 4, Telemecanique Safety light curtains XUSL, XUSL Body protection, Std sensing range, 3 Beams, Hp = 810 mm
Quick view
primary_image
Close

variable speed drive, Altivar 212, 18.5kW, 25hp, 240V, 3 phases, without EMC, IP21

variable speed drive, Altivar 212, 18.5kW, 25hp, 240V, 3 phases, without EMC, IP21
Quick view
primary_image
Close

Harmony XB4, Light block with body/fixing collar, metal, blue, integral LED, 24 V AC/DC, 2 NO

Harmony XB4, Light block with body/fixing collar, metal, blue, integral LED, 24 V AC/DC, 2 NO
Quick view
primary_image
Close

Disconnect switch, TeSys VLS, body switch, 100A, 50HP at 480VAC, UL98, three phase, 50kA SCCR, size 2, door mount

Disconnect switch, TeSys VLS, body switch, 100A, 50HP at 480VAC, UL98, three phase, 50kA SCCR, size 2, door mount
Quick view
  • LOCATION

    305 Clearview Rd, Suite 2
    Edison, NJ 08837

  • PHONE

    (201)617-5800 |

    FAX

    (201)617-5557

  • EMAIL

    sales@cuny.biz

Contact

201-617-5800

Hours of Operations: Counter Hours: 6:30am - 5pm Office Hours: 8am - 5pm Monday - Friday
Product Line
  • Contractor Supplies
  • Machine Control
  • Electrical Enclosures
  • Distribution
  • Circuit Protection
  • Automation
Contact Us Copyright 2020 Cuny & Guerber, Inc All Rights Reserved
  • Home
  • About Us
    • History
    • Capabilities
  • Product Lines
    • Automation
    • Circuit Protection
    • Distribution
    • Electrical Enclosures
    • Machine Control
    • Motor Control
    • Contractor Supplies
  • Schneider Catalog
  • Contact Us
    • Careers
Scroll To Top