TeSys LR9D electronic overload relay, 2A/690V, thermal setting range 0.4-2A, selectable tripping class 5-10-20-30, for protection of 3-phase motors 0.12-0.75kW@400V. Differential device with phase failure and load unbalance detection. It provides a thermal adjustement dial, buttons for test, stop and reset as well as manual-automatic reset selector, dipswitches for tripping class selection, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. With a large thermal setting range 0.4-2A, a selectable tripping class 5-10-20-30 and phase unbalance detection, it protects motors 0.18 to 0.75kW@400V. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D09-D38. Mounting on DIN rail or screw fixing, separated from contactor, with use of the terminal block LAD7B205 (to be ordered separately). Multi-standards certified (IEC, UL, CSA, CCC), Green Premium compliant (RoHs/Reach).
Overload relay, TeSys LRD, motor protection, 0.4A to 2A, 3 phase, withstand 6kV impulse, 2kV surge, electronic thermal
Overload relay, TeSys LRD, motor protection, 0.4A to 2A, 3 phase, withstand 6kV impulse, 2kV surge, electronic thermal
SKU: 501430
Category: Automation & Control
Reviews (0)
Be the first to review “Overload relay, TeSys LRD, motor protection, 0.4A to 2A, 3 phase, withstand 6kV impulse, 2kV surge, electronic thermal” Cancel reply
Related products
Contactor, Definite Purpose, 40A, 2 pole, 7.5 HP at 230 VAC, 1 phase, 440/480 VAC 50/60 Hz coil, open
Contactor, Definite Purpose, 40A, 2 pole, 7.5 HP at 230 VAC, 1 phase, 440/480 VAC 50/60 Hz coil, open
Disconnect Switch, TeSys LK4 Non fusible, 50hp at 600VAC, 3 pole, max 100A rated, plate mount
Disconnect Switch, TeSys LK4 Non fusible, 50hp at 600VAC, 3 pole, max 100A rated, plate mount
TeSys Deca thermal overload relays – 23…32 A – class 10A
TeSys Deca thermal overload relays - 23...32 A - class 10A
discrete output module Modicon Quantum – 32 O – positive logic (source)
discrete output module Modicon Quantum - 32 O - positive logic (source)
Mechanical alternator, Square D Pumptrol, closed tank, NEMA 1, screw in bushing, 4NC DPST DB contacts
Mechanical alternator, Square D Pumptrol, closed tank, NEMA 1, screw in bushing, 4NC DPST DB contacts
TeSys K reversing contactor – 3P – AC-3 <= 440 V 9 A – 1 NC – 24 V AC coil
TeSys K reversing contactor - 3P - AC-3 <= 440 V 9 A - 1 NC - 24 V AC coil
Reviews
There are no reviews yet.