These Square D heavy duty safety switches are designed to provide exceptional electrical protection in the most grueling conditions. They have been designed to have a significantly higher durability than a standard switch and have a durability three times greater than NEMA standard. Some of the things that make these switches desirable is there reliability, life durability, ease to install and safety features. Due to this, these heavy duty switches are the ideal for your electrical disconnect and protection for all your commercial and industrial needs. This is a three pole fusible heavy duty safety switch that is rated at 30A with voltage of 600 VAC and 600 VDC. It is rated when using time delay fuses of 15 HP at 240 VAC single phase, 20 HP at 600 VAC three phase and 15 HP at 600 VDC. This switch has a 3 wire configuration and is rated for 12 to 6 AWG aluminum wire and 14 to 6 AWG copper wire. This device has enclosure rating of NEMA 12 and it is made of galvannealed steel. It has a height of 16.5 in, width of 10.5 in and has a depth of 7 in. It is UL listed with the file E2875.
Safety switch, heavy duty, fusible, 30A, 3 poles, 20hp, 20hp, 600VAC/DC, Type 4, 4X, 5, 304 stainless steel, neutral
Safety switch, heavy duty, fusible, 30A, 3 poles, 20hp, 20hp, 600VAC/DC, Type 4, 4X, 5, 304 stainless steel, neutral
SKU: 15727543
Category: Automation & Control
Reviews (0)
Be the first to review “Safety switch, heavy duty, fusible, 30A, 3 poles, 20hp, 20hp, 600VAC/DC, Type 4, 4X, 5, 304 stainless steel, neutral” Cancel reply
Related products
Contactor, Definite Purpose, 30A, 2 pole, 110/120VAC 50/60Hz coil, open
Contactor, Definite Purpose, 30A, 2 pole, 110/120VAC 50/60Hz coil, open
TeSys Deca thermal overload relays – 23…32 A – class 10A
TeSys Deca thermal overload relays - 23...32 A - class 10A
Harmony XB4, Light block with body/fixing collar, metal, blue, integral LED, 24 V AC/DC, 2 NO
Harmony XB4, Light block with body/fixing collar, metal, blue, integral LED, 24 V AC/DC, 2 NO
Contactor, Definite Purpose, 40A, 2 pole, 7.5 HP at 230 VAC, 1 phase, 440/480 VAC 50/60 Hz coil, open
Contactor, Definite Purpose, 40A, 2 pole, 7.5 HP at 230 VAC, 1 phase, 440/480 VAC 50/60 Hz coil, open
variable speed drive, Altivar 212, 18.5kW, 25hp, 240V, 3 phases, without EMC, IP21
variable speed drive, Altivar 212, 18.5kW, 25hp, 240V, 3 phases, without EMC, IP21
Inductive proximity sensors XS for hazardous area dust, M12, Sn4mm, 12…48 VDC, NC, cable 10 m
Inductive proximity sensors XS for hazardous area dust, M12, Sn4mm, 12...48 VDC, NC, cable 10 m
Safety light curtain type 4, Telemecanique Safety light curtains XUSL, XUSL Body protection, Std sensing range, 3 Beams, Hp = 810 mm
Safety light curtain type 4, Telemecanique Safety light curtains XUSL, XUSL Body protection, Std sensing range, 3 Beams, Hp = 810 mm
Mechanical alternator, Square D Pumptrol, closed tank, NEMA 1, screw in bushing, 4NC DPST DB contacts
Mechanical alternator, Square D Pumptrol, closed tank, NEMA 1, screw in bushing, 4NC DPST DB contacts
Reviews
There are no reviews yet.