Surgelogicâ„¢ internally mounted surge protection devices delivers specification grade performance for service entrance or critical branch I-Line panel applications. These multiphase systems provide suppression, enchanced EFI/RFI filtering for all critical modes inside electrical equipment, and shorter lead lengths with superior SPD performance. They provide better performance with a diagnostic interface with push to test diagnostic switches, red and green status LEDs, module status LEDs per mode, dry contacts, audible alarm with disable switch, and a surge counter. These products have a 10 year product warranty and 10 modes of protection. This surge protection device is 3 phase, 4-wire + ground, 208Y/277 V, 50 kA breaking capacity, 160 kA surge current, and short circuit current rating of 200 kA. The device is engineered to UL 489 11th Edition, type 2 SPD and complies with UL 96A 12th Edition Master Label for Lightning Protection Systems.
Surge protection device, Surgelogic, HL, 160kA, 208Y/120VAC, 3 phase, 4 wire, SPD type 1
Surge protection device, Surgelogic, HL, 160kA, 208Y/120VAC, 3 phase, 4 wire, SPD type 1
SKU: 172569523
Category: Distribution Devices
Reviews (0)
Be the first to review “Surge protection device, Surgelogic, HL, 160kA, 208Y/120VAC, 3 phase, 4 wire, SPD type 1” Cancel reply
Related products
Surge Protect – IMA – HL – 200kA – 240VAC delta – 3P3W – T2
Surge Protect - IMA - HL - 200kA - 240VAC delta - 3P3W - T2
Surge Protect – EMA – 120kA – 600VAC delta – 3P3W – T4X – SW
Surge Protect - EMA - 120kA - 600VAC delta - 3P3W - T4X - SW
Surge protection module, Surgelogic, MA, 120kA, 208Y/120 VAC, 3 phase, 4 wire, SPD type 2, L-L enhanced
Surge protection module, Surgelogic, MA, 120kA, 208Y/120 VAC, 3 phase, 4 wire, SPD type 2, L-L enhanced
Surge Protect – EMA – 320kA – 240VAC delta – 3P3W – T1
Surge Protect - EMA - 320kA - 240VAC delta - 3P3W - T1
Surge protection device, Surgelogic, type ICSE, 2A, 120 V, flange, active tracking filter
Surge protection device, Surgelogic, type ICSE, 2A, 120 V, flange, active tracking filter
Surge protection device, Surgelogic, 320kA, 480Y/277 VAC, 3 phase, 4 wire, NEMA 4X
Surge protection device, Surgelogic, 320kA, 480Y/277 VAC, 3 phase, 4 wire, NEMA 4X
Surge Protect – IMA – HR – 160kA – 480VAC delta – 3P3W – T1
Surge Protect - IMA - HR - 160kA - 480VAC delta - 3P3W - T1
Surge mod IMA – 100kA – 480VAC delta – 3P3W – T2 – CSA
Surge mod IMA - 100kA - 480VAC delta - 3P3W - T2 - CSA
Reviews
There are no reviews yet.