8911 definite purpose starters are inexpensive starters for applications with relatively low duty cycles. Typical applications include air compressors, agricultural equipment, pumps, and HVAC equipment. This three pole definite purpose starter has a full load rating of 40 amperes. This starter has ratings of 3 HP at 115 VAC and 7.5 HP at 230 VAC single phase. It also has a rating of 10 HP at 230 VAC, 20 HP at 460 VAC and 25 HP at 575 VAC poly phase. The nonreplaceable coil is available with a variety of coil voltages. This device has a 208 to 240 VAC 60 HZ and 220 VAC 50 Hz coil. The starter has straight through wiring. The melting alloy type overload relay uses Type B thermal units to sense over current conditions. A painted sheet steel NEMA 1 general purpose enclosure is used to protect this definite purpose starter. Enclosure is 10.00 inches tall, 6.00 inches wide and 5.56 inches deep. Auxiliary contacts are available for these starters. 8911DPS definite purpose starters are UL component recognized.
Starter, Definite Purpose, nonreversing, 40A, 3 pole, 3 phase, 208V to 240V AC coil, melting alloy overload, NEMA 1
Starter, Definite Purpose, nonreversing, 40A, 3 pole, 3 phase, 208V to 240V AC coil, melting alloy overload, NEMA 1
SKU: 15546504
Category: Starters & Contactors
Reviews (0)
Be the first to review “Starter, Definite Purpose, nonreversing, 40A, 3 pole, 3 phase, 208V to 240V AC coil, melting alloy overload, NEMA 1” Cancel reply
Related products
Non-Reversing Contactor, Size 2, 2-Pole, Open Style +Options
Non-Reversing Contactor, Size 2, 2-Pole, Open Style +Options
Contactor, Type L, multipole lighting, mechanically held, 30A, 3 pole, 600 V, 110/120 VAC 50/60 Hz coil, NEMA 3R/12
Contactor, Type L, multipole lighting, mechanically held, 30A, 3 pole, 600 V, 110/120 VAC 50/60 Hz coil, NEMA 3R/12
TeSys F – specific contactor coil – 110 V AC 40…400 Hz low consumption
TeSys F - specific contactor coil - 110 V AC 40...400 Hz low consumption
TeSys D contactor – 4P(4 NO) – AC-1 – <= 440 V 60 A – 12 V DC standard coil
TeSys D contactor - 4P(4 NO) - AC-1 - <= 440 V 60 A - 12 V DC standard coil
Contactor, Type S, combination lighting, electrically held, 30A, 3 pole, breaker, 440/480 VAC 50/60 Hz coil, NEMA 1
Contactor, Type S, combination lighting, electrically held, 30A, 3 pole, breaker, 440/480 VAC 50/60 Hz coil, NEMA 1
Contactor, Type L, multipole lighting, mechanically held, 30A, 10 pole, 600 V, 110/120 VAC 50/60 Hz coil, open style
Contactor, Type L, multipole lighting, mechanically held, 30A, 10 pole, 600 V, 110/120 VAC 50/60 Hz coil, open style
NEMA Motor Starter, Type S, nonreversing, Size 3, 90A, 50 HP at 460 VAC, 5 kA SCCR, 2 phase, 4 pole, melting alloy, 240 VAC coil, NEMA 1
NEMA Motor Starter, Type S, nonreversing, Size 3, 90A, 50 HP at 460 VAC, 5 kA SCCR, 2 phase, 4 pole, melting alloy, 240 VAC coil, NEMA 1