8911 definite purpose starters are inexpensive starters for applications with relatively low duty cycles. Typical applications include air compressors, agricultural equipment, pumps, and HVAC equipment. This three pole definite purpose starter has a full load rating of 25 amperes. This starter has ratings of 2 HP at 115 VAC and 5 HP at 230 VAC single phase. It has a 10 HP at 230 VAC, 15 HP at 460 VAC and 20 HP at 575 VAC three phase. The nonreplaceable coil is available with a variety of coil voltages. This device has a 220/208 to 240 VAC 50/60 Hz coil. The starter has straight through wiring. The melting alloy type overload relay uses Type B thermal units to sense over current conditions. This definite purpose contactor is an open device without an enclosure. Enclosure is 6.73 inches tall, 3.50 inches wide and 4.09 inches deep. Auxiliary contacts are available for these starters. 8911DPS definite purpose starters are UL component recognized.
NEMA starter, Definite Purpose, 25A, 20HP at 600VAC, 3 phase, 3 pole, melting alloy, 208V to 240VAC coil, open
NEMA starter, Definite Purpose, 25A, 20HP at 600VAC, 3 phase, 3 pole, melting alloy, 208V to 240VAC coil, open
SKU: 14508720
Category: Starters & Contactors
Reviews (0)
Be the first to review “NEMA starter, Definite Purpose, 25A, 20HP at 600VAC, 3 phase, 3 pole, melting alloy, 208V to 240VAC coil, open” Cancel reply
Related products
NEMA Motor Starter, Type S, nonreversing, Size 3, 90A, 50 HP at 460 VAC, 5 kA SCCR, 2 phase, 4 pole, melting alloy, 240 VAC coil, NEMA 1
NEMA Motor Starter, Type S, nonreversing, Size 3, 90A, 50 HP at 460 VAC, 5 kA SCCR, 2 phase, 4 pole, melting alloy, 240 VAC coil, NEMA 1
Contactor, Type S, multipole lighting, electrically held, 400A, 3 pole, 550/600 V 50/60 Hz coil, open style
Contactor, Type S, multipole lighting, electrically held, 400A, 3 pole, 550/600 V 50/60 Hz coil, open style
Contactor, Type L, multipole lighting, mechanically held, 30A, 6 pole, 600 V, 110/120 VAC 50/60 Hz coil, NEMA 1, +option
Contactor, Type L, multipole lighting, mechanically held, 30A, 6 pole, 600 V, 110/120 VAC 50/60 Hz coil, NEMA 1, +option
Contactor, Type S, multipole lighting, mechanically held, 200A, 2 pole, 440/480 VAC 50/60 Hz coil, NEMA 12
Contactor, Type S, multipole lighting, mechanically held, 200A, 2 pole, 440/480 VAC 50/60 Hz coil, NEMA 12
Contactor TeSys LC1-K – 3 poles – AC-3 440V 9 A – coil 24 V AC
Contactor TeSys LC1-K - 3 poles - AC-3 440V 9 A - coil 24 V AC
Contactor, TeSys K, 3P, AC-3, lt or eq to 440V 9A, 1 NC aux., 24VAC coil
Contactor, TeSys K, 3P, AC-3, lt or eq to 440V 9A, 1 NC aux., 24VAC coil
Ambient Compensated Bimetallic Thermal Unit Class 20
Ambient Compensated Bimetallic Thermal Unit Class 20