Type S NEMA reversing magnetic starters are used for full voltage starting, stopping, and reversing AC squirrel cage motors. NEMA 8736 reversing starters are available in NEMA Sizes 00 to 7 and have ratings up to 810 amperes. NEMA reversing starters consist of two 8502S NEMA contactors that are mechanically and electrically interlocked and an overload relay. Sizes 0-5 reversing starters are available in either horizontal or vertical arrangements. This reversing starter is arranged horizontally. This 3 pole NEMA Size 2 reversing starter has an 45 ampere rating. This three phase NEMA Size 2 reversing starter has 10 HP at 200 VAC, 15 HP at 230 VAC and 25 HP at 460 and 575 VAC ratings. This reversing NEMA motor starter has a Motor Logic overload relay with a 15A to 45A Class 30 range to sense over current conditions. This NEMA starter has a 100 kA maximum SCCR (Short Circuit Current Rating) per UL508A when protected by an appropriate circuit breaker or fuse. Type S motor starters are available with replaceable coils in a wide variety of voltages. This starter has a 110/120 VAC 50/60 Hz operating coil wired for separate control. This NEMA reversing starter is an open device without an enclosure. This starter is 8.50 inches tall, 9.00 inches wide and 6.03 inches deep. A wide variety of accessories are available for Type S starters. Type S reversing NEMA motor starters are UL listed and CSA certified.
NEMA starter, Type S, reversing, horizontal, Size 2, 45A, 25HP at 575VAC, up to 100kA SCCR, 3 phase, 3 pole, Motor Logic SSOLR, 120VAC coil, open
NEMA starter, Type S, reversing, horizontal, Size 2, 45A, 25HP at 575VAC, up to 100kA SCCR, 3 phase, 3 pole, Motor Logic SSOLR, 120VAC coil, open
SKU: 1264788
Category: NEMA Contactors & Starters
Reviews (0)
Be the first to review “NEMA starter, Type S, reversing, horizontal, Size 2, 45A, 25HP at 575VAC, up to 100kA SCCR, 3 phase, 3 pole, Motor Logic SSOLR, 120VAC coil, open” Cancel reply
Related products
NEMA combination starter, Type S, fusible disconnect, fuse clip kit, class R fuse, 60A, 600 V, NEMA 2 or 60A contactor
NEMA combination starter, Type S, fusible disconnect, fuse clip kit, class R fuse, 60A, 600 V, NEMA 2 or 60A contactor
IEC contactor, TeSys Deca, nonreversing, 12A, 7.5HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 220VAC 50/60Hz coil, open
IEC contactor, TeSys Deca, nonreversing, 12A, 7.5HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 220VAC 50/60Hz coil, open
TeSys F contactor – 3P (3 NO) – AC-3 – <= 440 V 225 A – coil 240 V AC
TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 225 A - coil 240 V AC
NEMA Motor Starter, Type S, nonreversing, Size 0, 18A, 5 HP at 460 VAC, up to 100 kA SCCR, 3 phase, 3 pole, Motor Logic, 120 VAC coil, open
NEMA Motor Starter, Type S, nonreversing, Size 0, 18A, 5 HP at 460 VAC, up to 100 kA SCCR, 3 phase, 3 pole, Motor Logic, 120 VAC coil, open
IEC contactor, TeSys Deca, nonreversing, 125A resistive, 4 pole, 4 NO, 48VAC 50/60Hz coil, open style
IEC contactor, TeSys Deca, nonreversing, 125A resistive, 4 pole, 4 NO, 48VAC 50/60Hz coil, open style
Thermal Unit, Type S, Type B, melting alloy, Class 20
Thermal Unit, Type S, Type B, melting alloy, Class 20
NEMA Motor Starter, Type S, nonreversing, Size 5, 270A, 200 HP at 460 VAC, 3 phase, 3 pole, melting alloy, 120 VAC coil, open, 10 kA SSCR
NEMA Motor Starter, Type S, nonreversing, Size 5, 270A, 200 HP at 460 VAC, 3 phase, 3 pole, melting alloy, 120 VAC coil, open, 10 kA SSCR
Reviews
There are no reviews yet.