Type S NEMA reversing magnetic starters are used for full voltage starting, stopping, and reversing AC squirrel cage motors. NEMA 8736 reversing starters are available in NEMA Sizes 00 to 7 and have ratings up to 810 amperes. NEMA reversing starters consist of two 8502S NEMA contactors that are mechanically and electrically interlocked and an overload relay. Sizes 0-5 reversing starters are available in either horizontal or vertical arrangements. This reversing starter is arranged horizontally. This 4 pole NEMA Size 1 reversing starter has an 27 ampere rating. This two phase NEMA Size 1 reversing starter has 7.5 HP at 200 and 230 VAC and 10 HP at 460 and 575 VAC ratings. This reversing NEMA motor starter has a melting alloy type overload relay that uses Type B thermal units to sense over current conditions. This NEMA starter has a 5 kA maximum SCCR (Short Circuit Current Rating) per UL508A when protected by an appropriate circuit breaker or fuse. Type S motor starters are available with replaceable coils in a wide variety of voltages. This starter has a 110/120 VAC 50/60 Hz operating coil wired for separate control. This NEMA reversing starter is an open device without an enclosure. This starter is 6.91 inches tall, 7.13 inches wide and 5.31 inches deep. A wide variety of accessories are available for Type S starters. Type S reversing NEMA motor starters are UL listed and CSA certified.
NEMA Starter, Type S, reversing, horizontal, Size 1, 27A, 10HP at 575VAC, 5kA SSCR, 2 phase, 4 pole, melting alloy overload, 120VAC coil, open
NEMA Starter, Type S, reversing, horizontal, Size 1, 27A, 10HP at 575VAC, 5kA SSCR, 2 phase, 4 pole, melting alloy overload, 120VAC coil, open
	
			
		SKU: 1433369
	
	Category: NEMA Contactors & Starters
	
	
							
											
				Reviews (0)
				
					
						
							
	
			
					
		
	
	
						
					
				
			
					
		Be the first to review “NEMA Starter, Type S, reversing, horizontal, Size 1, 27A, 10HP at 575VAC, 5kA SSCR, 2 phase, 4 pole, melting alloy overload, 120VAC coil, open” Cancel reply	
				Related products
NEMA Contactor, Type S, nonreversing, Size 3, 90A, 50HP at 575VAC, 3 phase, up to 100kA, 3 pole, 120VAC coil, NEMA 1
					NEMA Contactor, Type S, nonreversing, Size 3, 90A, 50HP at 575VAC, 3 phase, up to 100kA, 3 pole, 120VAC coil, NEMA 1				
			NEMA combination starter, Type S, fusible disconnect, fuse clip kit, class R fuse, 60A, 600 V, NEMA 2 or 60A contactor
					NEMA combination starter, Type S, fusible disconnect, fuse clip kit, class R fuse, 60A, 600 V, NEMA 2 or 60A contactor				
			NEMA Combination Starter, Type S, nonfusible disconnect, Size 1, 27A, 10HP at 600VAC, 3 phase, 3 pole, melting alloy, 120VAC coil, NEMA 12
					NEMA Combination Starter, Type S, nonfusible disconnect, Size 1, 27A, 10HP at 600VAC, 3 phase, 3 pole, melting alloy, 120VAC coil, NEMA 12				
			Thermal Unit, Type S, Type CC, melting alloy, Class 20
					Thermal Unit, Type S, Type CC, melting alloy, Class 20				
			IEC contactor, TeSys Deca, nonreversing, 20A resistive, 4 pole, 2 NO and 2 NC, 24VDC coil, open style
					IEC contactor, TeSys Deca, nonreversing, 20A resistive, 4 pole, 2 NO and 2 NC, 24VDC coil, open style				
			TeSys F contactor – 3P (3 NO) – AC-3 – <= 440 V 225 A – coil 240 V AC
					TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 225 A - coil 240 V AC				
			IEC contactor, TeSys Deca, nonreversing, 18A, 10HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, low consumption 12VDC coil
					IEC contactor, TeSys Deca, nonreversing, 18A, 10HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, low consumption 12VDC coil				
			TeSys Deca reversing contactor – 3P(3 NO) – AC-3 – <= 440 V 18 A – 48 V AC coil
					TeSys Deca reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 18 A - 48 V AC coil				
			 
		
 
								 
								 
		 
		 
		 
		 
		 
		 
		 
		
Reviews
There are no reviews yet.