Type S NEMA reversing magnetic starters are used for full voltage starting, stopping, and reversing AC squirrel cage motors. NEMA 8736 reversing starters are available in NEMA Sizes 00 to 7 and have ratings up to 810 amperes. NEMA reversing starters consist of two 8502S NEMA contactors that are mechanically and electrically interlocked and an overload relay. Sizes 0-5 reversing starters are available in either horizontal or vertical arrangements. This reversing starter is arranged horizontally. This 3 pole NEMA Size 00 reversing starter has a 9 ampere rating. This three phase NEMA Size 00 reversing starter has 1.5 HP at 200 and 230 VAC and 2 HP at 460 and 575 VAC ratings. This reversing NEMA motor starter has a Motor Logic overload relay with a 1.5A to 4.5A Class 30 range to sense over current conditions. This NEMA starter has a 100 kA maximum SCCR (Short Circuit Current Rating) per UL508A when protected by an appropriate circuit breaker or fuse. Type S motor starters are available with replaceable coils in a wide variety of voltages. This starter has a 110/120 VAC 50/60 Hz operating coil wired for separate control. This NEMA reversing starter is an open device without an enclosure. This starter is 6.91 inches tall, 7.13 inches wide and 5.31 inches deep. A wide variety of accessories are available for Type S starters. Type S reversing NEMA motor starters are UL listed and CSA certified.
NEMA Starter, Type S, reversing, horizontal, Size 00, 9A, 2 HP at 575 VAC, up to 100 kA SCCR, 3 phase, 3 pole, Motor Logic SSOLR, 120 VAC coil, open
NEMA Starter, Type S, reversing, horizontal, Size 00, 9A, 2 HP at 575 VAC, up to 100 kA SCCR, 3 phase, 3 pole, Motor Logic SSOLR, 120 VAC coil, open
SKU: 1424035
Category: Starters & Contactors
Reviews (0)
Be the first to review “NEMA Starter, Type S, reversing, horizontal, Size 00, 9A, 2 HP at 575 VAC, up to 100 kA SCCR, 3 phase, 3 pole, Motor Logic SSOLR, 120 VAC coil, open” Cancel reply
Related products
NEMA starter, Type S, reversing, vertical, Size 3, 90A, 50HP at 575VAC, 5kA SSCR, 3 phase, 3 pole, melting alloy overload, 120VAC coil, open
NEMA starter, Type S, reversing, vertical, Size 3, 90A, 50HP at 575VAC, 5kA SSCR, 3 phase, 3 pole, melting alloy overload, 120VAC coil, open
NEMA Contactor, Type S, nonreversing, Size 1, 27A, 10 HP at 575 VAC, 3 phase, up to 100 kA, 3 pole, 120 VAC coil, open
NEMA Contactor, Type S, nonreversing, Size 1, 27A, 10 HP at 575 VAC, 3 phase, up to 100 kA, 3 pole, 120 VAC coil, open
NEMA Contactor, Type S, reversing, horizontal, Size 00, 9A, 1 HP at 230 VAC, single phase, up to 100 kA, 2 pole, 208 VAC coil, open style
NEMA Contactor, Type S, reversing, horizontal, Size 00, 9A, 1 HP at 230 VAC, single phase, up to 100 kA, 2 pole, 208 VAC coil, open style
Contactor, Type L, multipole lighting, mechanically held, 30A, 10 pole, 600 V, 277 VAC 60 Hz coil, NEMA 1, +option
Contactor, Type L, multipole lighting, mechanically held, 30A, 10 pole, 600 V, 277 VAC 60 Hz coil, NEMA 1, +option
TeSys D contactor – 4P(4 NO) – AC-1 – <= 440 V 80 A – 12 V AC 50 Hz coil
TeSys D contactor - 4P(4 NO) - AC-1 - <= 440 V 80 A - 12 V AC 50 Hz coil
Contactor, Type S, multipole lighting, electrically held, 400A, 3 pole, 550/600 V 50/60 Hz coil, open style
Contactor, Type S, multipole lighting, electrically held, 400A, 3 pole, 550/600 V 50/60 Hz coil, open style
TeSys D contactor – 4P(4 NO) – AC-1 – <= 440 V 60 A – 12 V DC standard coil
TeSys D contactor - 4P(4 NO) - AC-1 - <= 440 V 60 A - 12 V DC standard coil
Reviews
There are no reviews yet.