HomeStarters & Contactors NEMA Starter, Type S, reversing, horizontal, Size 0, 18A, 2 HP at 230 VAC, 5 kA SSCR, 1 phase, 3 pole, melting alloy overload, 120 VAC coil, NEMA 1
Previous product
primary_image
Square D Pumptrol, pump or compressor switch 9013GS, adjustable diff., 60 80 PSI
Back to products
Next product
primary_image
8903L electrically held lighting contactor, 6 P, 6 NO, 30 A, 600 V, 110/120 V 50/60 Hz coil, NEMA 1

NEMA Starter, Type S, reversing, horizontal, Size 0, 18A, 2 HP at 230 VAC, 5 kA SSCR, 1 phase, 3 pole, melting alloy overload, 120 VAC coil, NEMA 1

NEMA Starter, Type S, reversing, horizontal, Size 0, 18A, 2 HP at 230 VAC, 5 kA SSCR, 1 phase, 3 pole, melting alloy overload, 120 VAC coil, NEMA 1

SKU: 16943336 Category: Starters & Contactors
Share
Facebook Twitter Pinterest linkedin Telegram
  • Description
  • Reviews (0)
Description

Type S NEMA reversing magnetic starters are used for full voltage starting, stopping, and reversing AC squirrel cage motors. NEMA 8736 reversing starters are available in NEMA Sizes 00 to 7 and have ratings up to 810 amperes. NEMA reversing starters consist of two 8502S NEMA contactors that are mechanically and electrically interlocked and an overload relay. Sizes 0-5 reversing starters are available in either horizontal or vertical arrangements. This reversing starter is arranged horizontally. This 3 pole NEMA Size 0 reversing starter has an 18 ampere rating. This single phase NEMA Size 0 reversing starter for a 4-wire split phase motor has 1 HP at 115 VAC and 2 HP at 230 VAC ratings. This reversing NEMA motor starter has a melting alloy type overload relay that uses Type B thermal units to sense over current conditions. This NEMA starter has a 5 kA maximum SCCR (Short Circuit Current Rating) per UL508A when protected by an appropriate circuit breaker or fuse. Type S motor starters are available with replaceable coils in a wide variety of voltages. This starter has a 110/120 VAC 50/60 Hz operating coil wired for common control. A painted sheet steel NEMA 1 general purpose enclosure is used to protect this starter. Enclosure is 11.88 inches tall, 11.88 inches wide and 7.53 inches deep. A wide variety of accessories are available for Type S starters. Type S reversing NEMA motor starters are UL listed and CSA certified.

Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “NEMA Starter, Type S, reversing, horizontal, Size 0, 18A, 2 HP at 230 VAC, 5 kA SSCR, 1 phase, 3 pole, melting alloy overload, 120 VAC coil, NEMA 1” Cancel reply

Your email address will not be published. Required fields are marked *

Related products

primary_image
Close

Contactor, Type L, multipole lighting, mechanically held, 30A, 3 pole, 600 V, 110/120 VAC 50/60 Hz coil, NEMA 3R/12

Contactor, Type L, multipole lighting, mechanically held, 30A, 3 pole, 600 V, 110/120 VAC 50/60 Hz coil, NEMA 3R/12
Quick view
primary_image
Close

IEC contactor, TeSys Deca, nonreversing, 32A, 20HP at 480VAC, 3 phase, 3 pole, 3 NO, 24VDC coil, open style

IEC contactor, TeSys Deca, nonreversing, 32A, 20HP at 480VAC, 3 phase, 3 pole, 3 NO, 24VDC coil, open style
Quick view
Placeholder
Close

TeSys D contactor – 4P(4 NO) – AC-1 – <= 440 V 80 A – 12 V AC 50 Hz coil

TeSys D contactor - 4P(4 NO) - AC-1 - <= 440 V 80 A - 12 V AC 50 Hz coil
Quick view
primary_image
Close

Contactor, Type L, multipole lighting, mechanically held, 30A, 10 pole, 600 V, 277 VAC 60 Hz coil, NEMA 1, +option

Contactor, Type L, multipole lighting, mechanically held, 30A, 10 pole, 600 V, 277 VAC 60 Hz coil, NEMA 1, +option
Quick view
primary_image
Close

Contactor, TeSys K, 3P, AC-3, lt or eq to 440V 9A, 1 NC aux., 24VAC coil

Contactor, TeSys K, 3P, AC-3, lt or eq to 440V 9A, 1 NC aux., 24VAC coil
Quick view
primary_image
Close

NEMA starter, Type S, reversing, vertical, Size 3, 90A, 50HP at 575VAC, 5kA SSCR, 3 phase, 3 pole, melting alloy overload, 120VAC coil, open

NEMA starter, Type S, reversing, vertical, Size 3, 90A, 50HP at 575VAC, 5kA SSCR, 3 phase, 3 pole, melting alloy overload, 120VAC coil, open
Quick view
primary_image
Close

TeSys F – specific contactor coil – 110 V AC 40…400 Hz low consumption

TeSys F - specific contactor coil - 110 V AC 40...400 Hz low consumption
Quick view
Placeholder
Close

TeSys D contactor – 4P(4 NO) – AC-1 – <= 440 V 60 A – 12 V DC standard coil

TeSys D contactor - 4P(4 NO) - AC-1 - <= 440 V 60 A - 12 V DC standard coil
Quick view
  • LOCATION

    305 Clearview Rd, Suite 2
    Edison, NJ 08837

  • PHONE

    (201)617-5800 |

    FAX

    (201)617-5557

  • EMAIL

    sales@cuny.biz

Contact

201-617-5800

Hours of Operations: Counter Hours: 6:30am - 5pm Office Hours: 8am - 5pm Monday - Friday
Product Line
  • Contractor Supplies
  • Machine Control
  • Electrical Enclosures
  • Distribution
  • Circuit Protection
  • Automation
Contact Us Copyright 2020 Cuny & Guerber, Inc All Rights Reserved
  • Home
  • About Us
    • History
    • Capabilities
  • Product Lines
    • Automation
    • Circuit Protection
    • Distribution
    • Electrical Enclosures
    • Machine Control
    • Motor Control
    • Contractor Supplies
  • Schneider Catalog
  • Contact Us
    • Careers
Scroll To Top