Well-Guard pumping plant panels are designed for pumping applications. These panels provide extra space for field installation of auxiliary equipment. These panels use Type S non-reversing magnetic starters. Panel has a 60A fusible disconnect switch for Class H or K fuses. This panel has a 3 pole NEMA Size 2 non-reversing starter that has a 45 ampere rating. This NEMA Size 2 starter has maximum of 10 HP and 15 HP ratings three phase. This non-reversing NEMA motor starter has a Motor Logic overload relay with a 15A to 45A range to sense over current conditions. This NEMA starter has a 5 kA maximum SCCR (Short Circuit Current Rating) per UL508A when protected by an appropriate circuit breaker or fuse. The starters in these panels are available with a wide variety of replaceable coil voltages. The starter in this device has a 220/240 VAC 50/60 Hz operating coil wired for common control. A painted sheet steel NEMA 3R rainproof enclosure is used to protect this starter. Enclosure is 39.05 inches tall, 13.73 inches wide and 9.70 inches deep. A wide variety of accessories are available for Type S starters. This pump panel is supplied with a START momentary push button and a HAND/OFF/AUTO selector switch. These NEMA pump panels with Type S starters are UL listed and marked Suitable for use as Service Equipment. They are also CSA certified.
Pump Panel, NEMA Type S, Well Guard, Size 2, 45A, 5kA SSCR, 15HP, 60A Class H and K fuse clip, Motor Logic SSOLR, 220/240VAC 50/60Hz coil, NEMA 3R
Pump Panel, NEMA Type S, Well Guard, Size 2, 45A, 5kA SSCR, 15HP, 60A Class H and K fuse clip, Motor Logic SSOLR, 220/240VAC 50/60Hz coil, NEMA 3R
SKU: 172549204
Category: Automation & Control
Reviews (0)
Be the first to review “Pump Panel, NEMA Type S, Well Guard, Size 2, 45A, 5kA SSCR, 15HP, 60A Class H and K fuse clip, Motor Logic SSOLR, 220/240VAC 50/60Hz coil, NEMA 3R” Cancel reply
Related products
Inductive proximity sensors XS for hazardous area dust, M12, Sn4mm, 12…48 VDC, NC, cable 10 m
Inductive proximity sensors XS for hazardous area dust, M12, Sn4mm, 12...48 VDC, NC, cable 10 m
communication module Profibus DP V1, Altivar, 12Mbps, 1 female SUB D9 connector
communication module Profibus DP V1, Altivar, 12Mbps, 1 female SUB D9 connector
Mechanical alternator, Square D Pumptrol, closed tank, NEMA 1, screw in bushing, 4NC DPST DB contacts
Mechanical alternator, Square D Pumptrol, closed tank, NEMA 1, screw in bushing, 4NC DPST DB contacts
Vacuum switch 9016G – adjustable scale – 2 thresholds – Set 0 to 23.8 InHg
Vacuum switch 9016G - adjustable scale - 2 thresholds - Set 0 to 23.8 InHg
Safety light curtain type 4, Telemecanique Safety light curtains XUSL, XUSL Body protection, Std sensing range, 3 Beams, Hp = 810 mm
Safety light curtain type 4, Telemecanique Safety light curtains XUSL, XUSL Body protection, Std sensing range, 3 Beams, Hp = 810 mm
Contactor, Definite Purpose, 30A, 2 pole, 110/120VAC 50/60Hz coil, open
Contactor, Definite Purpose, 30A, 2 pole, 110/120VAC 50/60Hz coil, open
Non-Reversing Contactor, Size 2, 3-Pole, Open Style +Options
Non-Reversing Contactor, Size 2, 3-Pole, Open Style +Options
TeSys K reversing contactor – 3P – AC-3 <= 440 V 9 A – 1 NC – 24 V AC coil
TeSys K reversing contactor - 3P - AC-3 <= 440 V 9 A - 1 NC - 24 V AC coil
Reviews