PowerPacTÂ Q-Frame circuit breakers are used for overcurrent protection and switching on 240VAC systems. They are rated for 240VAC operational voltage and provide thermal magnetic trip protection. PowerPacT Q circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT Q, 100A, 3 pole, circuit breaker has an interrupting rating of 65kA at 208Y/120VAC and 240VAC. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. PowerPacT Q circuit breakers comply to UL, CSA, and NOM standards and are IEC certified.
Circuit breaker, PowerPacT Q, 100A, 3 pole, 240VAC, 65kA, I-Line, thermal magnetic, 80%, ABC
Circuit breaker, PowerPacT Q, 100A, 3 pole, 240VAC, 65kA, I-Line, thermal magnetic, 80%, ABC
SKU: 15710923
Category: Circuit Breakers
Reviews (0)
Be the first to review “Circuit breaker, PowerPacT Q, 100A, 3 pole, 240VAC, 65kA, I-Line, thermal magnetic, 80%, ABC” Cancel reply
Related products
Mini circuit breaker, QOU, 20A, 2 pole, 120/240 VAC, 10kA, mounting foot
Mini circuit breaker, QOU, 20A, 2 pole, 120/240 VAC, 10kA, mounting foot
Circuit breaker, PowerPacT H, thermal magnetic, unit mount, 60A, 3 pole, 18 kA, 600 VAC, shunt trip, copper lugs, 80%
Circuit breaker, PowerPacT H, thermal magnetic, unit mount, 60A, 3 pole, 18 kA, 600 VAC, shunt trip, copper lugs, 80%
Circuit breaker, PowerPacT H, 15A, 3 pole, 600VAC, 25kA, lugs, thermal magnetic, 80%, shunt
Circuit breaker, PowerPacT H, 15A, 3 pole, 600VAC, 25kA, lugs, thermal magnetic, 80%, shunt
Circuit breaker, PowerPacT B, 30A, 3 pole, 600Y/347VAC, 14kA, lugs, thermal magnetic, 80%
Circuit breaker, PowerPacT B, 30A, 3 pole, 600Y/347VAC, 14kA, lugs, thermal magnetic, 80%
Circuit breaker, PowerPacT H, 50A, 3 pole, 600VAC, 25kA, lugs, thermal magnetic, 100%
Circuit breaker, PowerPacT H, 50A, 3 pole, 600VAC, 25kA, lugs, thermal magnetic, 100%
Circuit breaker, PowerPacT B, 125A, 1 pole, 600Y/347VAC, 18kA, I-Line, thermal magnetic, 80%, A
Circuit breaker, PowerPacT B, 125A, 1 pole, 600Y/347VAC, 18kA, I-Line, thermal magnetic, 80%, A
Second MX voltage release, MasterPact MTZ1 drawout, remote tripping, 277VAC 50/60Hz
Second MX voltage release, MasterPact MTZ1 drawout, remote tripping, 277VAC 50/60Hz
Circuit breaker frame, MasterPact MTZ2 32H2, 3200A, 100kA/440VAC 50/60Hz (Icu), 4P, drawout, without control unit
Circuit breaker frame, MasterPact MTZ2 32H2, 3200A, 100kA/440VAC 50/60Hz (Icu), 4P, drawout, without control unit
Reviews
There are no reviews yet.