9050JCK plug in timers are designed to provide low cost timing in a plug in housing. This timer has a one shot timing mode. Input voltage must be applied continuously. When the customer supplied trigger switch closes, the timer relay contacts change state and the preset delay begins. During timing, the trigger signal is ignored. If the input voltage is removed, the timer relay contacts return to their shelf state. The timing range of 0.1 to 10 seconds is easily adjustable with a knob on the top of the timer. This plug in timer plugs into an 8501NR61 or 8501NR62 relay socket. These relay sockets can be mounted on 35 mm DIN 3 mounting track or directly to a panel. All wiring is made to the relay socket. The DPDT contacts are rated 10 amperes resistive at 120 VAC, 240 VAC and 30 VDC, 3 amperes inductive at 120 VAC, 240 VAC and 30 VDC, 1/3 HP on the NC contacts at 120 VAC and 240 VAC, 1/2 HP on the NO contacts at 120 VAC and 240 VAC. This plug in timer is powered up with 24 VAC/VDC. 9050JCK plug in timers are UL listed when the proper 8501NR relay socket is used, UL component recognized and CSA certified.
Timing Relay, Type JCK, plug In, one shot, adjustable time, 0.1 to 10 seconds, 10A, 240 VAC, 24 VAC/DC
Timing Relay, Type JCK, plug In, one shot, adjustable time, 0.1 to 10 seconds, 10A, 240 VAC, 24 VAC/DC
SKU: 494390
Category: Automation & Control
Reviews (0)
Be the first to review “Timing Relay, Type JCK, plug In, one shot, adjustable time, 0.1 to 10 seconds, 10A, 240 VAC, 24 VAC/DC” Cancel reply
Related products
Non-Reversing Contactor, Size 2, 3-Pole, Open Style +Options
Non-Reversing Contactor, Size 2, 3-Pole, Open Style +Options
Inductive proximity sensors XS for hazardous area dust, M12, Sn4mm, 12…48 VDC, NC, cable 10 m
Inductive proximity sensors XS for hazardous area dust, M12, Sn4mm, 12...48 VDC, NC, cable 10 m
Mechanical alternator, Square D Pumptrol, closed tank, NEMA 1, screw in bushing, 4NC DPST DB contacts
Mechanical alternator, Square D Pumptrol, closed tank, NEMA 1, screw in bushing, 4NC DPST DB contacts
Contactor, Definite Purpose, 30A, 2 pole, 110/120VAC 50/60Hz coil, open
Contactor, Definite Purpose, 30A, 2 pole, 110/120VAC 50/60Hz coil, open
Vacuum switch 9016G – adjustable scale – 2 thresholds – Set 0 to 23.8 InHg
Vacuum switch 9016G - adjustable scale - 2 thresholds - Set 0 to 23.8 InHg
Harmony XB5S, Protective cover for Biometric switch
Harmony XB5S, Protective cover for Biometric switch
Modular box PC, Harmony iPC, HMIBM Performance DC Base unit 8 GB 4 slots
Modular box PC, Harmony iPC, HMIBM Performance DC Base unit 8 GB 4 slots
variable speed drive, Altivar 212, 18.5kW, 25hp, 240V, 3 phases, without EMC, IP21
variable speed drive, Altivar 212, 18.5kW, 25hp, 240V, 3 phases, without EMC, IP21

Reviews
There are no reviews yet.