Type S NEMA motor starters are used for full voltage starting and stopping of AC squirrel cage motors. Type S motor starters have ratings up to 810 amperes. This 2 pole NEMA Size 1 non-reversing starter has a 27 ampere rating. This NEMA Size 1 motor starter has single phase ratings of 2 HP at 115 VAC and 3 HP at 230 VAC. This non-reversing NEMA motor starter has a melting alloy type overload relay that uses Type B thermal units to sense over current conditions. This NEMA starter has a 5 kA maximum SCCR (Short Circuit Current Rating) per UL508A when protected by an appropriate circuit breaker or fuse. Type S motor starters are available with replaceable coils in a wide variety of voltages. This starter has a 110/120 VAC 50/60 Hz operating coil wired for common control. A painted sheet steel NEMA 1 general purpose enclosure is used to protect this starter. Enclosure is 10.00 inches tall, 6.00 inches wide and 5.56 inches deep. A wide variety of accessories are available for Type S starters. Type S non-reversing NEMA motor starters are UL listed and CSA certified.
NEMA Motor Starter, Type S, nonreversing, Size 1, 27A, 3 HP at 230 VAC, 5 kA SCCR, 1 phase, 2 pole, melting alloy, 120 VAC coil, NEMA 1
NEMA Motor Starter, Type S, nonreversing, Size 1, 27A, 3 HP at 230 VAC, 5 kA SCCR, 1 phase, 2 pole, melting alloy, 120 VAC coil, NEMA 1
SKU: 15257327
Category: Starters & Contactors
Reviews (0)
Be the first to review “NEMA Motor Starter, Type S, nonreversing, Size 1, 27A, 3 HP at 230 VAC, 5 kA SCCR, 1 phase, 2 pole, melting alloy, 120 VAC coil, NEMA 1” Cancel reply
Related products
Contactor, NIGHT MASTER, combination lighting, 30A, 3 pole, breaker, 24 VAC 60 Hz coil. NEMA 3R
Contactor, NIGHT MASTER, combination lighting, 30A, 3 pole, breaker, 24 VAC 60 Hz coil. NEMA 3R
Panelboard lighting contactor auxiliary contact module, top assembly, 1NO-1NC
Panelboard lighting contactor auxiliary contact module, top assembly, 1NO-1NC
Contactor, TeSys K, 3P, AC-3, lt or eq to 440V 9A, 1 NC aux., 24VAC coil
Contactor, TeSys K, 3P, AC-3, lt or eq to 440V 9A, 1 NC aux., 24VAC coil
Contactor, Type L, multipole lighting, mechanically held, 30A, 6 pole, 600 V, 110/120 VAC 50/60 Hz coil, NEMA 1, +option
Contactor, Type L, multipole lighting, mechanically held, 30A, 6 pole, 600 V, 110/120 VAC 50/60 Hz coil, NEMA 1, +option
Contactor, Type S, multipole lighting, mechanically held, 200A, 2 pole, 440/480 VAC 50/60 Hz coil, NEMA 12
Contactor, Type S, multipole lighting, mechanically held, 200A, 2 pole, 440/480 VAC 50/60 Hz coil, NEMA 12
IEC contactor, TeSys Deca, nonreversing, 32A, 20HP at 480VAC, 3 phase, 3 pole, 3 NO, 24VDC coil, open style
IEC contactor, TeSys Deca, nonreversing, 32A, 20HP at 480VAC, 3 phase, 3 pole, 3 NO, 24VDC coil, open style
Contactor, Type S, multipole lighting, electrically held, 400A, 3 pole, 550/600 V 50/60 Hz coil, open style
Contactor, Type S, multipole lighting, electrically held, 400A, 3 pole, 550/600 V 50/60 Hz coil, open style
Non-Reversing Contactor, Size 2, 2-Pole, Open Style +Options
Non-Reversing Contactor, Size 2, 2-Pole, Open Style +Options
Reviews
There are no reviews yet.