Type S non-reversing magnetic contactors are used to switch heating loads, capacitors, transformers, and electric motors where overload protection is provided separately. Type S contactors have ratings up to 810 amperes. This 3 pole NEMA Size 5 non-reversing contactor has a 270 ampere rating. Three phase NEMA Size 5 contactors have 75 HP at 200, 100 HP at 230 VAC and 200 HP at 460 and 575 VAC ratings. This NEMA contactor has a 100 kA maximum SCCR rating per UL508A when protected by an appropriate circuit breaker or fuse. These contactors are available with replaceable coils in a wide variety of voltages. This contactor has a 110/120 VAC 50/60 Hz coil that is wired for separate control. This NEMA contactor is in a NEMA 1 general purpose enclosure. This enclosure is 44.22 inches tall, 17.22 inches wide and 12.81 inches deep. A wide variety of accessories are available for Type S contactors. Type S NEMA contactors are UL listed and CSA certified.
NEMA Contactor, Type S, nonreversing, Size 5, 270A, 200HP at 575VAC, 3 phase, up to 100kA, 3 pole, 120VAC coil, NEMA 1
NEMA Contactor, Type S, nonreversing, Size 5, 270A, 200HP at 575VAC, 3 phase, up to 100kA, 3 pole, 120VAC coil, NEMA 1
SKU: 14835437
Category: NEMA Contactors & Starters
Reviews (0)
Be the first to review “NEMA Contactor, Type S, nonreversing, Size 5, 270A, 200HP at 575VAC, 3 phase, up to 100kA, 3 pole, 120VAC coil, NEMA 1” Cancel reply
Related products
NEMA Motor Starter, Type S, nonreversing, Size 5, 270A, 200 HP at 460 VAC, 3 phase, 3 pole, melting alloy, 120 VAC coil, open, 10 kA SSCR
NEMA Motor Starter, Type S, nonreversing, Size 5, 270A, 200 HP at 460 VAC, 3 phase, 3 pole, melting alloy, 120 VAC coil, open, 10 kA SSCR
IEC contactor, TeSys Deca, nonreversing, 32A, 20HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 380VAC 50/60Hz coil, open
IEC contactor, TeSys Deca, nonreversing, 32A, 20HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 380VAC 50/60Hz coil, open
NEMA combination starter, Type S, 60A fusible disconnect, Size 2, 45A, 25HP at 600VAC, 3 phase, 3 pole, Motor Logic SSOLR, 120VAC coil, NEMA 1
NEMA combination starter, Type S, 60A fusible disconnect, Size 2, 45A, 25HP at 600VAC, 3 phase, 3 pole, Motor Logic SSOLR, 120VAC coil, NEMA 1
IEC contactor, TeSys Deca, nonreversing, 12A, 7.5HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 220VAC 50/60Hz coil, open
IEC contactor, TeSys Deca, nonreversing, 12A, 7.5HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 220VAC 50/60Hz coil, open
TeSys Deca reversing contactor – 3P(3 NO) – AC-3 – <= 440 V 25 A – 220 V AC coil
TeSys Deca reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 220 V AC coil
NEMA combination starter, Type S, fusible disconnect, fuse clip kit, class R fuse, 60A, 600 V, NEMA 2 or 60A contactor
NEMA combination starter, Type S, fusible disconnect, fuse clip kit, class R fuse, 60A, 600 V, NEMA 2 or 60A contactor
TeSys F contactor – 3P (3 NO) – AC-3 – <= 440 V 115 A – coil 380 V AC
TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 115 A - coil 380 V AC
IEC contactor, TeSys Deca, nonreversing, 20A resistive, 4 pole, 2 NO and 2 NC, 24VDC coil, open style
IEC contactor, TeSys Deca, nonreversing, 20A resistive, 4 pole, 2 NO and 2 NC, 24VDC coil, open style
Reviews
There are no reviews yet.