Type S non-reversing magnetic contactors are used to switch heating loads, capacitors, transformers, and electric motors where overload protection is provided separately. Type S contactors have ratings up to 810 amperes. This 3 pole NEMA Size 3 non-reversing contactor has a 90 ampere rating. Three phase NEMA Size 3 contactors have 25 HP at 200, 30 HP at 230 VAC and 50 HP at 460 and 575 VAC ratings. This NEMA contactor has a 100 kA maximum SCCR rating per UL508A when protected by an appropriate circuit breaker or fuse. These contactors are available with replaceable coils in a wide variety of voltages. This contactor has a 220/240 VAC 50/60 Hz coil that is wired for common control. This NEMA contactor is in a NEMA 1 general purpose enclosure. This enclosure is 21.81 inches tall, 11.44 inches wide and 8.00 inches deep. A wide variety of accessories are available for Type S contactors. Type S NEMA contactors are UL listed and CSA certified.
NEMA Contactor, Type S, nonreversing, Size 3, 90A, 50 HP at 575 VAC, 3 phase, up to 100 kA, 3 pole, 240 VAC coil, NEMA 1
NEMA Contactor, Type S, nonreversing, Size 3, 90A, 50 HP at 575 VAC, 3 phase, up to 100 kA, 3 pole, 240 VAC coil, NEMA 1
SKU: 13518369
Category: Starters & Contactors
Reviews (0)
Be the first to review “NEMA Contactor, Type S, nonreversing, Size 3, 90A, 50 HP at 575 VAC, 3 phase, up to 100 kA, 3 pole, 240 VAC coil, NEMA 1” Cancel reply
Related products
Contactor, Type L, multipole lighting, mechanically held, 30A, 10 pole, 600 V, 277 VAC 60 Hz coil, NEMA 1, +option
Contactor, Type L, multipole lighting, mechanically held, 30A, 10 pole, 600 V, 277 VAC 60 Hz coil, NEMA 1, +option
Contactor, Type S, multipole lighting, mechanically held, 200A, 2 pole, 440/480 VAC 50/60 Hz coil, NEMA 12
Contactor, Type S, multipole lighting, mechanically held, 200A, 2 pole, 440/480 VAC 50/60 Hz coil, NEMA 12
Contactor, NIGHT MASTER, combination lighting, 30A, 3 pole, breaker, 24 VAC 60 Hz coil. NEMA 3R
Contactor, NIGHT MASTER, combination lighting, 30A, 3 pole, breaker, 24 VAC 60 Hz coil. NEMA 3R
Contactor TeSys LC1-K – 3 poles – AC-3 440V 9 A – coil 24 V AC
Contactor TeSys LC1-K - 3 poles - AC-3 440V 9 A - coil 24 V AC
TeSys D contactor – 4P(4 NO) – AC-1 – <= 440 V 60 A – 12 V DC standard coil
TeSys D contactor - 4P(4 NO) - AC-1 - <= 440 V 60 A - 12 V DC standard coil
NEMA Motor Starter, Type S, nonreversing, Size 3, 90A, 50 HP at 460 VAC, 5 kA SCCR, 2 phase, 4 pole, melting alloy, 240 VAC coil, NEMA 1
NEMA Motor Starter, Type S, nonreversing, Size 3, 90A, 50 HP at 460 VAC, 5 kA SCCR, 2 phase, 4 pole, melting alloy, 240 VAC coil, NEMA 1
NEMA Contactor and NEMA Motor Starter, Type S, nonreversing, enclosure, NEMA Size 00, 0, 1, 8903SM lighting, NEMA 3R
NEMA Contactor and NEMA Motor Starter, Type S, nonreversing, enclosure, NEMA Size 00, 0, 1, 8903SM lighting, NEMA 3R
Reviews
There are no reviews yet.