Facebook Twitter Pinterest linkedin Telegram
Cuny & Guerber Cuny & Guerber
  • Home
  • About Us
    • History
    • Capabilities
  • Product Lines
    • Automation
    • Circuit Protection
    • Distribution
    • Electrical Enclosures
    • Machine Control
    • Motor Control
    • Contractor Supplies
  • Schneider Catalog
  • Contact Us
    • Careers
Menu
Cuny & Guerber
primary_image
Click to enlarge
HomeAutomation & Control NEMA Starter, Type S, reversing, horizontal, Size 1, 27A, 10 HP at 575 VAC, 5 kA SSCR, 3 phase, 3 pole, melting alloy overload, 120 VAC coil, NEMA 1
Previous product
primary_image
Tubes, square 50 mm, length: 1,5m. For SPACIAL S3CM HMI encl.
Back to products
Next product
primary_image
Operating mechanism, flange mounted, bracket mount, fixed depth assembly, 200A, 600V, no fuse, switch mechanism, 6 inch handle

NEMA Starter, Type S, reversing, horizontal, Size 1, 27A, 10 HP at 575 VAC, 5 kA SSCR, 3 phase, 3 pole, melting alloy overload, 120 VAC coil, NEMA 1

NEMA Starter, Type S, reversing, horizontal, Size 1, 27A, 10 HP at 575 VAC, 5 kA SSCR, 3 phase, 3 pole, melting alloy overload, 120 VAC coil, NEMA 1

SKU: 172548740 Category: Automation & Control
Share
Facebook Twitter Pinterest linkedin Telegram
  • Description
  • Reviews (0)
Description

Type S NEMA reversing magnetic starters are used for full voltage starting, stopping, and reversing AC squirrel cage motors. NEMA 8736 reversing starters are available in NEMA Sizes 00 to 7 and have ratings up to 810 amperes. NEMA reversing starters consist of two 8502S NEMA contactors that are mechanically and electrically interlocked and an overload relay. Sizes 0-5 reversing starters are available in either horizontal or vertical arrangements. This reversing starter is arranged horizontally. This 3 pole NEMA Size 1 reversing starter has an 27 ampere rating. This three phase NEMA Size 1 reversing starter has 7.5 HP at 200 and 230 VAC and 10 HP at 460 and 575 VAC ratings. This reversing NEMA motor starter has a melting alloy type overload relay that uses Type B thermal units to sense over current conditions. This NEMA starter has a 5 kA maximum SCCR (Short Circuit Current Rating) per UL508A when protected by an appropriate circuit breaker or fuse. Type S motor starters are available with replaceable coils in a wide variety of voltages. This starter has a 110/120 VAC 50/60 Hz operating coil wired for separate control. A painted sheet steel NEMA 1 general purpose enclosure is used to protect this starter. Enclosure is 11.88 inches tall, 11.88 inches wide and 7.53 inches deep. A wide variety of accessories are available for Type S starters. Type S reversing NEMA motor starters are UL listed and CSA certified.

Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “NEMA Starter, Type S, reversing, horizontal, Size 1, 27A, 10 HP at 575 VAC, 5 kA SSCR, 3 phase, 3 pole, melting alloy overload, 120 VAC coil, NEMA 1” Cancel reply

Your email address will not be published. Required fields are marked *

Related products

Placeholder
Close

TeSys K reversing contactor – 3P – AC-3 <= 440 V 9 A – 1 NC – 24 V AC coil

TeSys K reversing contactor - 3P - AC-3 <= 440 V 9 A - 1 NC - 24 V AC coil
Quick view
primary_image
Close

variable speed drive, Altivar 212, 18.5kW, 25hp, 240V, 3 phases, without EMC, IP21

variable speed drive, Altivar 212, 18.5kW, 25hp, 240V, 3 phases, without EMC, IP21
Quick view
primary_image
Close

TeSys Deca thermal overload relays – 23…32 A – class 10A

TeSys Deca thermal overload relays - 23...32 A - class 10A
Quick view
primary_image
Close

Inductive proximity sensors XS for hazardous area dust, M12, Sn4mm, 12…48 VDC, NC, cable 10 m

Inductive proximity sensors XS for hazardous area dust, M12, Sn4mm, 12...48 VDC, NC, cable 10 m
Quick view
primary_image
Close

Contactor, Definite Purpose, 30A, 2 pole, 110/120VAC 50/60Hz coil, open

Contactor, Definite Purpose, 30A, 2 pole, 110/120VAC 50/60Hz coil, open
Quick view
primary_image
Close

Mureva BOX – grommet – grey – diameter 4 to 20

Mureva BOX - grommet - grey - diameter 4 to 20
Quick view
primary_image
Close

communication module Profibus DP V1, Altivar, 12Mbps, 1 female SUB D9 connector

communication module Profibus DP V1, Altivar, 12Mbps, 1 female SUB D9 connector
Quick view
primary_image
Close

Disconnect switch, TeSys VLS, body switch, 100A, 50HP at 480VAC, UL98, three phase, 50kA SCCR, size 2, door mount

Disconnect switch, TeSys VLS, body switch, 100A, 50HP at 480VAC, UL98, three phase, 50kA SCCR, size 2, door mount
Quick view
  • LOCATION

    305 Clearview Rd, Suite 2
    Edison, NJ 08837

  • PHONE

    (201)617-5800 |

    FAX

    (201)617-5557

  • EMAIL

    sales@cuny.biz

Contact

201-617-5800

Hours of Operations: Counter Hours: 6:30am - 5pm Office Hours: 8am - 5pm Monday - Friday
Product Line
  • Contractor Supplies
  • Machine Control
  • Electrical Enclosures
  • Distribution
  • Circuit Protection
  • Automation
Contact Us Copyright 2020 Cuny & Guerber, Inc All Rights Reserved
  • Home
  • About Us
    • History
    • Capabilities
  • Product Lines
    • Automation
    • Circuit Protection
    • Distribution
    • Electrical Enclosures
    • Machine Control
    • Motor Control
    • Contractor Supplies
  • Schneider Catalog
  • Contact Us
    • Careers
Scroll To Top